Stel THOR 103 Manual De Instrucciones página 53

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
THOR 103
COD. 6909500060
9.2– FAULT - CAUSE - REMEDY
PROBLEM
The ON/OFF switch is in position 1 but the
1) There is no power present at input of the
green Led (mains) does not light up).
THOR.
2) The line fuse is broken.
The generator is on, but the green GAS
1 ) The air pressure is low.
PRESSURE Led does not light up.
1) The generator is still overheated. It will
The generator is on, but the yellow
cool down sooner with the fan on.
EXCESS TEMPERATURE Led remains
lit.
2) The temperature sensor is faulty.
The generator is on, the red Led remains
1) The generator is not enabled; a safety
lit.
device has been activated.
The generator is on, the red Led remains
1) A safety device has been activated.
lit after resetting with the RESET button.
The magnetothermal switch which pro-
1) The power required by the generator
tects the line trips during cutting.
has exceeded the power available on
line.
2) Another appliance is working on the
same line.
The pilot arc does not strike, or the arc
1) Presence of oxide on the replaceable
disappears during cutting.
parts of the torch.
2) The replaceable parts of the torch are
worn.
3) The generator is overheated.
4) There is not sufficient air pressure.
5) There is low voltage on the incoming
line.
The pilot is working but there is not suffi-
1) Bad contact of the earth clamp.
cient current for cutting.
2) Bad connection of the positive pole at
output.
The cut is not perpendicular.
1) Worn electrode or tip.
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail: stel @ stelgroup.it
http: www.stelgroup.it
TECHNICAL
DESCRIPTION
CAUSE
SOLUTION
1) Check the power supply and change the
line fuse if necessary.
1) Check that the air filter is not blocked.
2) Increase the air pressure.
1) Switch on the generator and wait a
few minutes before working again.
2) Call the STEL assistance centre.
1) Press the RESET button.
1) Check the air pressure.
2) Check that the torch cap is well closed.
3) Check that the side panel has been correctly closed
(torch connector inspection side)
1) Reduce the cutting current with the command
on the front panel or reduce the cutting time.
2) Reduce the length of the connecting cable or
increase the cable section.
3) Do not connect other appliances to the same
line as the THOR.
1) Change the worn parts or remove the oxide
with a wire brush.
2) Check the torch and fit spare parts if
necessary.
3) See the yellow SAFETY led on the front panel:
if it is lit, wait until the generator cools down.
4) See the green GAS led on the front panel: if it
is off, increase the air pressure.
4.1) Check whether the air filter is blocked and
replace it if necessary.
5) Check the incoming line. If an extension is being
used, ensure that the cable section is adequate.
1) Check that the earth clamp has a good
contact with the piece to be cut.
2) Check the connection of the positive pole at
output to the socket, even on the inside.
1) Replace the electrode and the tip.
ENGLISH
9.2– FAULT - CAUSE - REMEDY
PROBLEM
The ON/OFF switch is in position 1 but the
green Led (mains) does not light up).
The generator is on, but the green GAS
PRESSURE Led does not light up.
The generator is on, but the yellow
EXCESS TEMPERATURE Led remains
lit.
The generator is on, the red Led remains
lit.
The generator is on, the red Led remains
lit after resetting with the RESET button.
The magnetothermal switch which pro-
tects the line trips during cutting.
The pilot arc does not strike, or the arc
disappears during cutting.
The pilot is working but there is not suffi-
cient current for cutting.
The cut is not perpendicular.
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail: stel @ stelgroup.it
53
http: www.stelgroup.it
TECHNICAL
THOR 103
COD. 6909500060
DESCRIPTION
CAUSE
SOLUTION
1) There is no power present at input of the
1) Check the power supply and change the
THOR.
line fuse if necessary.
2) The line fuse is broken.
1) Check that the air filter is not blocked.
1 ) The air pressure is low.
2) Increase the air pressure.
1) The generator is still overheated. It will
1) Switch on the generator and wait a
cool down sooner with the fan on.
few minutes before working again.
2) Call the STEL assistance centre.
2) The temperature sensor is faulty.
1) The generator is not enabled; a safety
1) Press the RESET button.
device has been activated.
1) Check the air pressure.
1) A safety device has been activated.
2) Check that the torch cap is well closed.
3) Check that the side panel has been correctly closed
(torch connector inspection side)
1) The power required by the generator
1) Reduce the cutting current with the command
on the front panel or reduce the cutting time.
has exceeded the power available on
line.
2) Reduce the length of the connecting cable or
increase the cable section.
2) Another appliance is working on the
same line.
3) Do not connect other appliances to the same
line as the THOR.
1) Presence of oxide on the replaceable
1) Change the worn parts or remove the oxide
with a wire brush.
parts of the torch.
2) Check the torch and fit spare parts if
2) The replaceable parts of the torch are
necessary.
worn.
3) See the yellow SAFETY led on the front panel:
3) The generator is overheated.
if it is lit, wait until the generator cools down.
4) There is not sufficient air pressure.
4) See the green GAS led on the front panel: if it
is off, increase the air pressure.
5) There is low voltage on the incoming
4.1) Check whether the air filter is blocked and
line.
replace it if necessary.
5) Check the incoming line. If an extension is being
used, ensure that the cable section is adequate.
1) Bad contact of the earth clamp.
1) Check that the earth clamp has a good
contact with the piece to be cut.
2) Bad connection of the positive pole at
2) Check the connection of the positive pole at
output.
output to the socket, even on the inside.
1) Worn electrode or tip.
1) Replace the electrode and the tip.
53