TROUBLESHOOTING

Fault Description
Machine inactive
(1) Power indicator not on
(2) Ice full level indicator on
(3) low water level indicator on
Ice production decreases
Ice machine in operation but no ice
produced
Noise of gear box is too high
16
All manuals and user guides at all-guides.com
Possible Causes
Main switch is set to OFF position
Connection wire get loosened
Malfunction of ice level control assembly
Blocked filters
Low water pressure
Regulation valve partially blocked or
improperly adjusted
Low water level of water bin
Insufficient feed of refrigerant
in water cylinder for ice Check water pump operation or replace
No water
production
Gear box motor gets stuck
Gear box damaged or leaks lubrication
oil
Gear box's bearing and teeth get worn
out
Recommendations
Knob selector need to be
set to ON position
Check the wiring
Clean or replace ice level control
assembly
Please refer to recommendations
for low water level alarm
Clean or replace filters
Adjust or replace float valve
Adjust float valve to set water level
Identify gas leakage and make a
refrigerant load
it
Check or replace it
Check or replace it