Descargar Imprimir esta página

KPS MT700 Manual De Instrucciones página 2

Multímetro digital

Publicidad

Idiomas disponibles

Idiomas disponibles

Description
• The multimeter is a portable, hand-held yet professional meter that features True
RMS measurement display, AC/DC current, AC/DC voltage, Frequency, Capacitance,
Resistance, Continuity, Duty Ratio, Diode Testing and a USB adapter for recording
readings on a PC. This Meter is easy to use even with one hand, suitable for professional
users or amateurs, and ideal for school or home use.
• Both auto and manual range.
• Display hold
• True RMS for AC voltage/current measurements
• Relative measurement
• Maximum measurement
• Minimum measurement
• Display frequency when measuring AC voltage/current
• Automatic Power Off
Safety Information
WARNING
Use caution and follow all safety guidelines to prevent electric shock or damage to the meter.
Please ready carefully all instructions before use. If the equipment is used in a manner not
specified by the manufacturer, the protection provided by the equipment may be impaired.
The multimeter meets the safety standards of EN/UL/CSA 61010-1, 61010-2-030,
61010-2-033 for electronic testing instruments. This meter meets CAT III 1000V,
CAT IV 600V installations and a pollution degree of 2.
Preparation
• When using the meter, follow all standard safety guidelines:
- For universal protection again electric shock.
- To prevent the misuse of the instrument.
• Check the meter for damage during transit.
• Test leads must be in good condition.Check the insulation and tips before use.
• Safety can only be guaranteed with leads provided.
• lf leads need to be replaced, they must be replaced with leads of same electrical
specifications.
Using the Meter
• Always set the meter to the proper function and range first.
• Never exceed protection limits indicated for each measurement.
• Keep fingers behind the probe barriers while measuring.
• Always be careful when working with voltages above 60V DC or 30V AC RMS.
• When using the CAT IV environment,if the measuring voltage between terminals and
earth ground exceeds 600V CAT III environments or voltage measurement between the
terminal and the earth more than 1000V, do not measure voltage.
• In manual range, if the circuit value is unknown, start the meter at the maximum range and
then adjust accordingly.
• Remove the leads from the circuit first before switching between functions.
• Do not power on circuit while measuring resistan ce, capacitance, diodes and continuity.
• Never connect the meter's leads across a voltage source while the rotary switch is in the
resistance,capacitance, diode or continuity mode.
• Do not measure capacitance befare capacitors are discharged.
• Do not operate the meter near explosive gas, vapor or dust.
• Stop using the meter if any abnormality is observed.
• Do not use the meter unless the battery cover is securely fastened to the meter.
• Avoid direct exposure to sunlight to ensure extended life of the meter.
Maintenance
• To avoid electric shock or personal injury, repairs/servicing not covered in this manual
should be performed only by qualified personnel.
• Remove test leads from any circuit before opening battery cover.
• To avoid false readings that may become dangerous, replace the battery as soon as
the
symbol appears.
• Clean the meter using a damp cloth and mild detergent only; do not use abrasives or
chemical solvents.
• Always move rotary switch to OFF when not using the meter.
• lf meter is not going to be used for an extended period of time, remove battery to prevent
damage to the meter.
Replacing the Battery and Fuse
WARNING
To avoid electrical shock or personal injury, before opening the battery cover to replace
battery, you should turn the meter off and make sure that the test probe is disconnected
from the measurement circuit.
To avoid wrong readings, electric shock or personal injury, when "
display, replace the battery immediately.
Use only a fuse with specified amperage, fusing rated
value, voltage rated value and fusing speed
( F1: FF 600mA H 1000V, F2: FF 10A H 1000V)
Please follow below steps to replace battery or fuse:
• Turn off the power supply of the meter.
• Pull out all test probes from the input socket.
• Loosen two screws on the fixed battery cover with screwdriver.
• Remove the battery cover.
• Remove the old battery or damaged fuse.
• Replace with a new battery with 9V (NEDA 1604, 6F22 or 006P) or a new fuse.
• Replace the battery cover and tighten the screws.
Note:
ENG
ENGLISH
Pay attention to the polarity of the battery to avoid damage to the meter.
Replacing Test Probe
If insulation on leads is damaged, replace it.
If the test leads need to be replaced, you must use a new one which should meet EN
61010-031 standard, rated CAT III 1000V/CAT IV 600V, 10A or better.
Accessories
Test leads
Summary instruction manual
Battery 9V 6F22
USB interface cable
USB interface software CD ROM disc
" appears on the meter
APAC: MGL GLOBAL SOLUTIONS LTD
info.apac@mgl-intl.com
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA: MGL EUMAN S.L.
info.emea@mgl-intl.com
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
Digital multimeter
WARNING
1 pair
1 pc
1 pc
1 pc
1 pc
See the full
instruction manual:
AMERICAS: MGL AMERICA, LLC.
info.na@mgl-intl.com
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
KPS SOLUCIONES EN ENERGÍA, S.L.
Tel: +1 833 533-5899
Parque Empresarial de Argame,
US West Coast: 760 Challenger Street.
C/Picu Castiellu, Parcelas i-1 a i-3
Brea, California 92821 USA
E-33163 Argame, Morcín
Tel: +1 310-728-6220
Asturias, España, (Spain)
www.mgl-intl.com
ENG

Publicidad

loading

Este manual también es adecuado para:

Kpsmt700cbint