Bradley Halo S19-500 Serie Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

S19-500 Series & S19-505 Series
2b
Install Faucet Hoses (S19-500M & S19-505M)
A
Set the valve body assembly in place.
B
Slide the retaining washer in place.
C
Thread the nut onto the thread rod and tighten the
nut to hold the valve assembly in place.
D
Plumb the output hose from the valve assembly
to the faucet hose, using the provided nipple and
fitting.
E
Plumb the eyewash hose to the eyewash supply,
and then plumb the faucet supply to the valve
assembly.
10
7/6/2021
Valve Body
Assembly
Valve Body
Assembly
Faucet Hose
(middle)
³⁄₈" Compression
Hot & Cold
Faucet Inlets
Close
³⁄₈"
Nipple
Compression
Adapter
(discard ferrule
and nut)
Bradley • 215-1910 Rev. D: ECO 21-05-013
Installation
Retaining
Washer
Threaded Rod
& Nut
Eyewash
Hose
½" NPSM
Eyewash Inlet
Output
Hose