Overview
Specifications
General specifications:
AC power source/power
requirements
Frequency
Power requirements,
direct current
V
Adaption to ambient
conditions
Display update (depends on
the filter level selected)
Specifications for the individual models:
BBL Series
Model
Weighing capacity
g
Readability
mg
Tare range (subtractive)
g
≤±mg
Repeatability
≤±mg
Linearity
Sensitivity drift within
≤±/K
+10...+30 °C/+50...+86°F
Response time (average)
s
External calibration weight
g
(of at least accuracy class...)
lb
Net weight, approx.
kg
Pan size
mm
Power consumption (average) W
Operating temperature range
Dimensions (W×D×H)
mm
BBL Series
Model
Weighing capacity
g
Readability
g
Tare range (subtractive)
g
≤±g
Repeatability
≤±g
Linearity
Sensitivity drift within
≤±/K
+10...+30 °C/+50...+86°F
Response time (average)
s
External calibration weight
g
(of at least accuracy class...)
lb
Net weight, approx.
kg
Pan size
mm
Hours of operation:
– with 9-volt battery, approx.
h
– with fully charged rechargeable
9-volt battery, approx.
h
Power consumption (average) W
Operating temperature range
Dimensions (W×D×H)
mm
12
All manuals and user guides at all-guides.com
AC adapter, 230 or 115 V,
+ 15%...–20%
48–60 Hz
10 to 20
By selection of 1 of 4 optimized
filter levels
0.1–0.4
BBL31
BBL32
210
120
0.1
0.1
210
120
0.1
0.1
0.2
0.2
2·10
–6
2·10
–6
3
3
200 (E2) 100 (E2)
0.4 (E2) 0.2 (E2)
3.0
3.0
80 Ø
80 Ø
1.0
+10...+30 °C (273...303 K)
(50...86 °F)
189×251×300
BBL42
BBL52
BBL53
BBL54
150
1,500
610
310
0.001
0.01
0.01
0.01
150
1,500
610
310
0.0015
0.015
0.01
0.01
0.003
0.03
0.02
0.02
3.3·10
–6
3.3·10
–6
0.5·10
–5
1·10
–5
2.5
2.5
2
2
100 (F1) 1000 (F1) 500 (F2) 100(F2)
0.2 (F1)
2 (F1)
1 (F2)
0.2 (F2)
1.6
1.4
1.1
1.1
100 Ø
150 Ø
115 Ø
115 Ø
–
–
11
11
–
–
2.5
2.5
0.75
0...+40 °C (263...313 K, 32 °F...104 °F)
189×251×70
(without glass draft shield cylinder)
BBL Series
Model
Weighing capacity
g
Readability
g
Tare range (subtractive)
g
≤±g 0.1
Repeatability
≤±g 0.2
Linearity
Sensitivity drift within
≤±/K 0,5·10
+10...+30 °C/+50...+86°F
Response time (average)
s
External calibration weight
g
(of at least accuracy class...)
lb
(F2)
Net weight, approx.
kg
Pan size
mm
Hours of operation:
– with 9-volt battery, approx.
h
– with fully charged
rechargeable 9-volt battery,
approx.
h
Power consumption (average) W
Operating temperature range
Dimensions (W×D×H)
mm
C Marking
The C marking affixed to the equipment indicates that the
equipment meets the requirements of the following Directive(s):
Council Directive 89/336/EEC
"Electromagnetic compatibility (EMC)"
Applicable European Standards:
Limitation of emissions:
According to Product Standard EN61326-1 Kl.B
(Residential environment)
Defined Immunity to Interference:
According to Product Standard EN61326-1
(Industrial environment)
Important Note:
The operator shall be responsible for any modifications to
BOECO equipment and for any connections of cables or
equipment not supplied by BOECO and must check and,
if necessary, correct these modifications and connections.
On request, BOECO will provide information on the minimum
operating specifications (in accordance with the Standards
listed above for defined immunity to interference).
Council Directive 73/23/EEC
"Electrical equipment designed for use within
certain voltage limits"
Applicable European Standards:
EN 60950
Safety of information technology equipment
including electrical business equipment
EN 61010
Safety requirements for electrical equipment
for measurement, control and laboratory use
Part 1: General requirements
If you use electrical equipment in installations and under
ambient conditions requiring higher safety standards,
you must comply with the provisions as specified in the
applicable regulations for installation in your country.
BBL61 BBL62 BBL63 BBL64 BBL71
6,100
3,100
1,500
610
6,000
0.1
0.1
0.1
0.1
1
6,100
3,100
1,500
610
6
0.1
0.1
0.1
1
0.2
0.2
0.2
2
–5
1·10
–5
2·10
–5
5·10
–5
5·10
–5
2
2
2
2
2
5,000
1,000
1,000
500
5,000
(F2)
(F2)
(M1)
(M1)
(M1)
10,000 2,000
2,000
1,000
10,000
(F2)
(M1)
(M1)
(M1)
1.4
1.4
1.4
1.4
1.4
150 Ø
11
11
11
11
11
2.5
2.5
2.5
2.5
2.5
0.75
0...+40 °C (263...313 K, 32 °F...104 °F)
189×251×70