Operating instructions
1
Hilti cardboard box or toolbox

2.7 Using extension cords

Use only extension cords of a type approved for the application and with conductors of adequate cross section. The
power tool may otherwise loose performance and the extension cord may overheat. Check the extension cord for
damage at regular intervals. Replace damaged extension cords.
Recommended minimum conductor cross section and max. cable lengths for the UD 16:
Conductor cross section
Mains voltage 100V
Mains voltage 110-120 V
Mains voltage 220-240 V
Recommended minimum conductor cross section and max. cable lengths for the UD 30:
Conductor cross section
Mains voltage 100V
Mains voltage 110-120 V
Mains voltage 220-240 V
Do not use extension cords with 1.25 mm² conductor cross section.
2.8 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this application.
2.9 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit
must provide a power output in watts of at least twice the value printed on the type identification plate on the power
tool. The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and
starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching other
power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the
power tool.

3 Accessories

The list of insert tools can be found in Section 2 under "Possible applications".
Designation
Keyless chuck
UD 16 keyed chuck
UD 16 chuck key (if keyed chuck is fitted)
UD 30 keyed chuck
UD 30 chuck key (if keyed chuck is fitted)
1.5 mm²
2 mm²
30 m
30 m
90 m
1.5 mm²
2 mm²
40 m
30 m
100 m
Item number, description
274077
274080
274082
274079
274081
2.5 mm²
3.5 mm²
50 m
50 m
140 m
2.5 mm²
3.5 mm²
60 m
50 m
160 m