STEP 4
CABLE ADAPTER
Bevel the end of the cable insulation at a 45_ angle, approximately 1/4" (6mm) back. Thoroughly clean, then lubricate cable
insulation always working toward semi---con shield. Install cable adapter, small end first, until it is flush with the edge of the
tape marker.
Tape Marker
STEP 5
CONDUCTOR
Remove the protruding cable insulation by cutting it even
with the end of the cable adapter. Do not cut or nick the
cable adapter or the conductor. The length of exposed
conductor should be between 4---1/4" -- 4--9/16"
(108mm---116mm). Otherwise redo assembly.
STEP 6
COMPRESSION LUG
Fully insert conductor into compression Lug.
Copper Conductor:
Aluminum Conductor: Wire brush conductor and immediately fully insert conductor into compression lug.
Measure the "Check Dimension" before crimping. This
dimension should be less than 6---3/8". Otherwise redo
assembly. Crimp the compression lug following the
crimping instructions supplied with the lug. Wipe all excess
inhibitor from compression lug and cable adapter surface
after crimping. The distance from the end of the
compression lug to the cable adapter after crimping should
be between 6---3/8" to 7---1/8" (162mm---181mm).
Otherwise redo assembly.
STEP 7
ELBOW
Lubricate cable adapter and inside of elbow cable
entrance. Install elbow onto cable adapter until the elbow
can not advance further. Make sure cable adapter is still
flush with tape marker. If not, reposition cable adapter.
Remove tape marker.
STEP 8
MATING PRODUCTS
DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED.
DO NOT ENERGIZE WHILE DISCONNECTED.
Remove protective caps from the elbow and the mating
part. Hand tighten the threaded stud supplied with the
elbow into mating part, if the mating part is not equipped
with a stud. Clean and lubricate both the elbow and the
mating part with lubricant supplied. (Keep surfaces of
elbow and mating part clean.)
Edge
Cable Insulation
Clean and
Lubricate
Clean &
Lubricate
Reducing
Tap Plug
Bevel
(108mm---116mm)
Even with Cable Adapter
Compression Lug
Cable
Adapter
Check Dimension
Before Crimping
Flush
Tape Marker
Threaded Stud
Clean &
Lubricate
Apparatus
Insulating
Bushing
Plug
Connector
Cable Adapter
Cable Adapter
4---1/4"--4--9/16"
Locate First Crimp
on this end
6---3/8" to 7---1/8"
(162mm---181mm)
After Crimping
Cable Adapter
Lubricate
Clean & Lubricate
Clean &
Lubricate
Reducing
Tap Well
Plug
IS- - 0249
March 2016
Page 3 of 10
Bare
Conductor
Elbow Tap
Plug