Please remember that the first lighting must be performed
by our certified Authorized Assistance Centre (Law 37/2008)
!
that verifies the installation and completes the guarantee.
During the first lighting the environment should be well
ventilated since during the first hours of operation unplea-
sant odours could develop due to the physical stabilizing of
the paint and from the grease in the tubyère wrapping.
2.3 Suggestions
• Do not continuously turn the stove on and off as this could provoke sparks that could shorten the life of the electrical
components.
• Do not touch the stove with wet hands: the stove has electrical components that could produce sparks if handled incor-
rectly. Only authorized technicians can resolve possible problems.
• Do not remove any screws from the fire chamber without first lubricating them well.
• Never open the glass door of the pellet stove while the stove is in operation.
• Be sure that the brazier basket is positioned correctly.
• The flue system must be suitable for inspecion. If it cannot be removed, it must have some holes for inspection and
cleaning.
2.4 How to load pellets in the tank
You can load pellets in the tank through the door on the upper part of the stove.
Join the following procedure to load pellets:
• Open the door on the upper part of the stove;
• Load the wished pellets quantity with caution (load enough pellets to grant a sufficient functioning of the stove);
• Close the door.
3.0 First Lighting of the Stove
3.1 Lighting the stove
• Fill the container 3/4 full with the pellets recommended by the manufacturer;
• Connect the stove to an electrical outlet with the cable that has been supplied;
• Press the lighting switch located on the back part of the stove;
• The upper display will read "off";
• Press the button
for 2 seconds. After a few moments the smoke extractor and the lighting resistor will start and
the display will read "START"; The led resistence is switched on.
• After 1 minute the display will read "LOAD PELLET", the stove will load the pellets and continue lighting the resistor;
• Once the appropriate temperature has been reached the display will read "FLAME LIGHT": this means that the stove has
begun the last phase in lighting, at the end of which the stove will be completely operational; The led resistence is switched
off.