All manuals and user guides at all-guides.com
6.7 Daily cleaning by scraper (where present)
With heater off and cold, activate 5-6 times the duct scraper of the heat exchange by raising and lowering the knob placed
in the compartment under the sliding front panel.
Fig. 12: non-operating scraper.
Fig. 11: operating scraper.
6.8 Cleaning of the flame beater
Remove the flame beater from its seat and proceed with cleaning according to the following procedure:
• Pull a few centimetres towards you the flame beater until it is released completely (1).
• Turn the flame beater by about 30° and extract it from the combustion chamber (2).
• Remove with an aspirator all the ash deposited on top of the flame beater.
• Replace the flame beater in its original position and make sure that it is securely inserted.
2
1
Fig. 13
40