Final Check
Check operation of electric igniters. Check flame
characteristics. Flame should be blue with no yellow tip.
Service
Before Calling Service
If the ignitors do not spark or the "on" indicator lights do not
glow, check the power source to see if a fuse has blown o
if the circuit breaker has tripped.
Refer to the Warranty in the Use and Care Manual. See
Use and Care manual for troubleshooting information.
Product Data Plate
The data plate shows the model and FD (product's unique
identifier for customer service) number of your cooktop. It
is located on the underside of the rough-in box, underne ath
the cooktop.
All manuals and user guides at all-guides.com
r
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or
mostly yellow, verify that the regulator is set for the
correct fuel. After adjustment, retest.
Some yellow streaking is norm al during the initial start-
up. Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.