Cleaning and care

• Wipe off powder coated surfaces with soft, moist rag. Do not clean heater with
cleaners that are combustible or corrosive.
• Remove debris from the burner to keep it clean and safe for use.
Problems check list
PROBLEM
Pilot will not light
Pilot will not stay on
Burner will not light
If the appliance is in case of any defaults or problems of assembly or use , please
don't try to modify it by yourself , contact your supplier or distributor to solve it.
12
PROBABLE CAUSE
Gas valve may be OFF
Tank fuel empty
Opening blocked
Air in supply system
Loose connections
Debris around pilot
Loose connections
Thermocouple bad
Gas leak in line
Lack of fuel pressure
Pressure is low
Opening is blocked
Control not ON
Thermocouple bad
Pilot light assembly bent
Not in correct location
SOLUTION
Turn the gas valve ON
Refill LPG tank
Clean or replace opnening
Purge air from lines
Check all fittings
Clean dirty area
Tighten connections
Replace thermocouple
Check connections
Tank near empty, refill LPG
Tank near empty, refill LPG
Remove and clean
Turn valve to ON
Replace thermocouple
Place pilot properly
Position properly and retry