Hazards encountered by the combination of water and electricity
• The combination of water and electricity can lead to death or severe injury from electrocution, if the unit is incorrectly
connected or misused.
• Prior to reaching into the water, always switch off the mains voltage to all units used in the water.
Correct electrical installation
• Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
• A person is regarded as a qualified electrician, if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the
recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regu-
lations.
• For your own safety, please consult a qualified electrician.
• The unit may only be connected when the electrical data of the unit and the power supply coincide. The unit data is
to be found on the unit type plate or on the packaging, or in this manual.
• Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
• Extension cables and power distributors (e. g. outlet strips) must be suitable for outdoor use.
• Protect the plug connections from moisture.
Safe operation
• Operation of the unit is only permitted with the protection hood fitted. This protects connections and plugs from rain
and splash water.
• The unit, the connections and plugs are not water-proof and must not be routed or installed in water.
• Never operate the unit if either the electrical cables or the housing are defective!
• Do not carry or pull the unit by its electrical cable.
• Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do not present a
tripping obstacle.
• Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
• Only execute work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
• Only use original spare parts and accessories for the unit.
• Never carry out technical modifications to the unit.
Unit configuration and function description
The FM-Master WLAN is a garden socket with integrated WLAN connection technology. The connected units can be
controlled via a smartphone or tablet and the FM-Master app.
Features:
• Four sockets that can be switched, one of which has a dimmer function.
• 24 hour control of each socket by means of an integrated timer.
• Up to 10 OASE units offering remote control can be additionally integrated and controlled via the app.
• Additional DMX/RDM connection for control of OASE garden bus compatible end devices such as AquaMax Eco Expert.
• Cover to protect against splash water allows the unit to be used throughout the year.