BATTERY SIZE/RATING
CARS/TRUCKS
MARINE/DEEP CYCLE
13.

MAINTENANCE INSTRUCTIONS

13.1
After use and before performing maintenance, unplug and disconnect the battery
charger (see sections 6, 7 and 8).
13.2
Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery clips,
cords, and the charger case.
13.3
Ensure that all of the charger components are in place and in good working condition,
for example, the plastic boots on the battery clips.
13.4
Servicing does not require opening the unit, as there are no user-serviceable parts.
13.5
All other servicing should be performed by qualified service personnel.
14.

MOVING AND STORAGE INSTRUCTIONS

14.1
Store the charger unplugged, in an upright position. The cord will still conduct electricity
until it is unplugged from the outlet.
14.2
Store inside, in a cool, dry place.
14.3
Do not store the clips on the handle, clipped together, on or around metal, or clipped
to cables.
14.4
If the charger is moved around the shop or transported to another location, take care to
avoid/prevent damage to the cords, clips and charger. Failure to do so could result in
personal injury or property damage.
15.
TROUBLESHOOTING AND FAILURE CODES
Failure Codes
FAILURE
CODE
The battery voltage is still
under 10V (for a 12V battery)
F01
or 5V (for a 6V battery) after 2
hours of charging.
The charger cannot desulfate
F02
the battery.
The battery was unable
F03
to reach the "full charged"
voltage.
The charger was unable to
F05
keep the battery fully charged
in maintain mode.
All manuals and user guides at all-guides.com
40 - 60 RC
200 - 315 CCA
(36 - 46 AH)
60 - 85 RC
315 - 550 CCA
(46 - 58 AH)
80 - 190 RC
550 - 1000 CCA
(58 - 111 AH)
80 RC
140 RC
160 RC
180 RC
DESCRIPTION
11
CHARGE RATE/CHARGING
2 AMP
20 AMP
11¼ -
1¼ - 1½
14½ hrs
NR
1½ - 2 hrs
NR
2 - 3½ hrs
NR
1¾ hrs
NR
2¾ hrs
NR
NR
3½ hrs
CAUSE
Could be caused by trying to charge a 6
volt battery on the 12 volt charger, or the
battery could be bad; have it checked or
replaced.
The battery could not be desulfated; have it
checked or replaced.
Could be caused by trying to charge a
large battery or bank of batteries on too
low of a current setting, or the battery may
have a shorted cell. Try again with a higher
current setting, or have the battery checked
or replaced.
The battery won't hold a charge. Could
be caused by a drain on the battery or
the battery could be bad. Make sure there
are no loads on the battery. If there are,
remove them. If there are none, have the
battery checked or replaced.
TIME
55 AMP
25 - 32
hrs
min
32 - 40
min
40 min -
1¼ hrs
NR
NR
3 hrs
NR
NR