Warning!
This basic apparatus is a pure gas protection device.
It is not suitable for underwater diving.
Use
(1) Connect the compressed air cylinder to the SCBA.
(2) Don the compressed air breathing apparatus.
(3) Condensed check prior to use.
(4) Don the mask and do the air-tight check.
(5) Open cylinder valve fully.
(6) Connect demand valve to full face mask.
(7) Don the inhale and exhale check.
During Use
(1) Regularly check tight fit of the mask and demand valve.
(2) Leave area immediately if the warning signal sounds.
Warning!
The warning signal sounds when the air supply in the
compressed air cylinders is reduced. In such cases,
immediately leave the area, there is danger of air
deficiency.
After Use
(1) Remove demand valve and full face mask.
(2) Unfasten waist belt.
(3) Take off device.
(4) Close cylinder valve.
(5) Completely release the remaining air in the system by pressing
the green button on the demand valve.
Warning!
Do not throw off device. This could damage the valve and
any remaining compressed air could escape suddenly. This
could cause fatal injury to you or to any bystanders.
(6) Remove cylinder from the device.
Order No.: 10168077/01