Unit Description; Mains Connection - Duronic SADV1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Immunity Test Standard
IEC 60601-1-2 Test Level
Electrostatic discharge (ESD)
IEC 61000-4-2
+2kV, +4kV, +8kV, +15kV air
Electrical fast transient/burst
+2kV, for power supply lines
IEC 61000-4-4
+1kV signal input/ output
100 kHz repetition frequency
Surge IEC 61000-4-5
+0.5kV, +1kV differential lines
+0.5kV, +1kV, +1kV common
Voltage dips, interruptions and
0 % UT; 0.5 cycle. At 0°, 45°, 90°,
variations on power supply input
135°, 180°, 225°, 270° and 315°.
lines
0 % UT; 1 cycle and 70 % UT;
IEC 61000-4-11
25/30 cycles; Single phase: at 0°.
0 % UT; 250/300 cycle
Power frequency
(50/60 Hz) magnetic field
IEC 61000-4-8
Conducted RF IEC 61000-4-6
0,15 MHz – 80 MHz
6 V in ISM and amateur radio
bands between 0,15 MHz and 80
80 % AM at 1 kHz
Radiated RF IEC
61000-4-3
80 MHz – 2,7 GHz 80 % AM at 1
Note: UT is the a.c. mians voltage prior to application of the test level.
The following symbols appear in this manual, on the "Daylight" or on its accessories:
Warning instruction indicating a
risk of injury or damage to health
Safety note indicating possible
damage to the appliance/ acces-
Specifies serial number of the
"Daylight"
O / I
OFF/ ON
Authorized Representative in the
EC/REP
European Community
IP20
Ingress Protection Rating
Compliance Level
+8kV contact
+8 kV contact
+2kV, +4kV, +8kV, +15kV air
+2kV, for power supply lines
Not applicable
100 kHz repetition frequency
+0.5kV, +1kV differential lines
Not Applicable
mode
0 % UT; 0.5 cycle. At 0°, 45°,
90°, 135°, 180°, 225°, 270°
and 315°.
0 % UT; 1 cycle and 70 % UT;
25/30 cycles;
Single phase: at 0°.
0 % UT; 250/300 cycle
30 A/m
30 A/m
50Hz/ 60Hz
50Hz/ 60Hz
3 V
3 V
0,15 MHz – 80 MHz
6 V in ISM and amateur radio
bands between 0,15 MHz and
MHz
80 MHz
80 % AM at 1 kHz
10 V/m
10 V/m
80 MHz – 2,7 GHz 80 % AM
kHz
at 1 kHz
Read operating
instructions before use
Caution: Consult
accompanying documents
Class II Equipment
Date of Manufacture
Manufacturer
Keep Dry
10

Unit Description

Setup
1. Remove the appliance from the packaging.
2. Fold the stand out and place the appliance on a solid surface, such as a
table.
3. Place the appliance approximately 20-60 cm from your eyes, the light must
bathe your face from the side.

Mains Connection

Connect the appliance only to the mains voltage listed on the type plate.
Push the plug completely into the mains socket.
Note
Push the plug completely into the mains socket.
Ensure that there is a socket near the place where the appliance will
stand.
Lay the mains cable in such a way that no one can trip over it.
Fastening of Daylight on the wall
There is a mounting hole on the back side of the appliance. At this mounting
hole the appliance can be fixed on the wall with screw. Depending on the
type of wall, an appropriate screw must be used, may be with pegs. E.g. for
concrete wall, M4, 25mm long Stainless Steel Self-Tapping Screw which is
screwed into a anchor.
The screw and the anchor are not included in the scope of delivery.
1. Screen
2. Brackets
3. Mounting hole
4. Carrying handle
5. Fold-out stand
6. On/ Off Switch
7. Retaining Clips
8. Reflector
9. Tubes, 2 x 36W
11

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido