3 . O P E R A T I O N S
3-1. Operating Mode/Status Description
Mode/Status
UPS Power On
AC Mode
ECO Mode
Converter Mode
Battery Mode
Bypass Mode
Battery Test Mode
Warning Status
Fault Mode
3-2. Button Operation
There are 4 buttons on front panel.
Button
ON/ENTER
OFF/ESC
UP
DOWN
UP + DOWN
14
All manuals and user guides at all-guides.com
When UPS is powered on, it will enter into this mode for a few seconds for initializing the
CPU and system.
When the input voltage is within acceptable range, and the UPS is turned on (the inverter is
running), the UPS will provide pure and stable sine wave AC voltage. The UPS will also
charge the battery in AC mode.
When the input voltage is within voltage regulation range and ECO mode is enabled, the
UPS will bypass voltage to output for energy saving. If the input voltage is out of the
regulation range but it is still within acceptable range of AC mode, the UPS will transfer to
inverter supplying the power to load (similar as AC mode).
When input frequency is within 46 to 64Hz, the UPS can be set with a constant output
frequency (50 Hz or 60 Hz) through the inverter. The UPS will still charge battery at this
mode. There is no bypass at this mode.
When the input voltage is out of the acceptable range or power failure, and the UPS is
turned on (the inverter is running), the UPS will backup power from battery.
When input voltage is within acceptable range and bypass is enabled, and the UPS
(inverter) is not turned on or the inverter can't support the load, the UPS will supply power
to the load through bypass.
When the UPS is in AC mode or Converter mode, and the battery test command is enabled
through LCD or monitoring software, the UPS will start Battery Test. This operation is used
to check the battery status.
If some errors occur in the UPS (but it is still running normally), buzzer will alarm and
warning code will appear in the LCD for trouble shooting.
When fatal error occurs in the UPS, it will beep continuously and go to fault mode. It will
display fault codes in LCD.
Function
Press this button to turn on the UPS.
Or press it to confirm the selection in the menu.
Press this button to turn off the UPS.
Or press it to return to last menu.
Press this button to select the previous item in the menu.
Or press this button to jump to previous page in the screen.
Or press this button to increase the number in the setting.
Press this button to select the next item in the menu.
Or press this button to jump to next page in the screen.
Or press this button to decrease the number in the setting.
To allow LCD display to rotate 90ºautomatically, press these two buttons at the same time.
This operation is used to configure the UPS in rack or tower display.