If nails are driven too shallow, turn the adjuster to the
deep side.
Turn Adjuster
2
Too Shallow
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTION.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.

RAFTER HOOK

With the NR83A5, NR83A5 (S) and NR83AA5, an
included hook can be attached by using three M5
fl ange bolts which are included with the tools. When the
tool is detached from the hose and not in use, the hook
can be used to store the unit.
WARNING
When attaching or detaching the hook, make
sure the hose is detached and the nails are
removed from the tool.
(1) How to attach the hook
Hexagonal bar wrench for M5
2
1
Main unit
Fig. 1
• When attaching, use a hexagonal bar wrench for M5
(separate).
22
000Book̲NR83A5̲US̲metabo.indb 22
000Book̲NR83A5̲US̲metabo.indb 22
• Fix the hook (1) to the main unit in three locations
using the M5
8.3±0.5 N
Flush
• The hook can be attached in any direction. Adjust the
hook according to the operating environment (Fig. 2).
(2) How to detach the hook
Detach the hook by reversing the aforementioned
steps for attaching the hook.
16
×
USING THE NOSE CAP (except NR83AA5)
If you like to protect the surface of workpiece against
scratches or markings made by the push lever, attach the
Fig. 2
accessory nose cap to the push lever.
1 DISCONNECT AIR HOSE FROM NAILER.
2 Put the nose cap to the toe of the push lever.
16 fl ange bolts (2) (Fig. 1).
×
Fastening Torque
m
6.1±0.4 ft.lbs
WARNING
When the hook is attached, operate only
with SINGLE SEQUENTIAL ACTUATION
MECHANISM
and
not
ACTUATION MECHANISM. For switching
between
SINGLE
SEQUENTIAL
CONTACT, see the appropriate section in
"METHODS OF OPERATION".
Disconnect the air hose when hook the unit.
Do not hook on high or unstable locations.
Also, do not hook it to the body, clothing, belt
or other personal items.
WARNING
Disconnect the air hose from the nailer
before attaching or removing the nose cap.
85±5 kgf
cm
with
CONTACT
and
2018/05/22 13:58:57