NOTE:
The nose cap may reduce nailing depth due to its
thickness. Re-adjustment of nailing depth is required.
Do not connect
1
air hose
NOTE: The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that di er from those on your own Nailer.
MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 4 – 8).
WARNING
Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Insert a rod into the outlet.
Tap the rod with a hammer.
Hammer
Rod
Outlet
000Book̲NR83A5̲US̲metabo.indb 23
000Book̲NR83A5̲US̲metabo.indb 23
Nose cap can be removed from the push lever using a
screwdriver or thin rod.
Nose
Push Lever
Nose Cap
MAINTENANCE
2. Inspecting the magazine
<NR83A5 / NR83A5 (S)>
Disconnect
1
air hose
Screwdriver
3 Remove the jammed nail with a slotted screw
driver.
4 In case of frequent jam, contact a metabo HPT
authorized service center.
1 DISCONNECT AIR HOSE.
2 Clean the magazine. Remove plastic tips or
wooden tips which may have accumulated in
the magazine. Lubricate it with metabo HPT
pneumatic tool lubricant.
Nail Feeder