ERROR CODE
DISPLAYED
POSSIBLE DEFECT
To remove an error code: 1. Unplug transformer.
Service: Timer/Softener, Service Checkout Procedure
If you are not getting soft water, and an error
code is not displayed, use the procedures below
to find the problem. First make the following
visual checks.
VISUAL CHECKS:
1. Is there electrical power to the outlet the
water softening system transformer is
plugged into?
NO SOFT
WATER
CONTROL DISPLAY SHOWS
CORRECT TIME AND DAY
AND IS STEADY.
14
All manuals and user guides at all-guides.com
ERR 01
• Motor
inoperative
• Wiring
harness or
connection
to switch
• Position
switch
• Control
2. Correct defect.
3. Plug transformer in.
4. Wait for at least 6 minutes. The error code will return if the reason for
the error code was not corrected.
CONTROL SHOWS
WRONG TIME AND DAY,
AND/OR IS FLASHING.
Check electrical
power to control
CONTROL
(outlet, transformer,
DISPLAY
power cable, all
BLANK.
connections).
Do manual
diagnostics.
ERR 02
ERR 03
• Position
• Motor
switch
inoperative
or wiring
harness
• Control
• Control
2. Is there sufficient salt in the storage tank?
3. Is the softener bypass valve directing water
for soft water service?
4. Is the valve drain hose open to the drain,
not more than 2m above the softener, and
unobstructed?
If you do not find a problem with the visual checks,
continue below.
Electrical power was off.
Reset the correct time of
day.
REPAIR AS
NO POWER
NEEDED
POWER OK
CONTROL
DEFECTIVE