TO TEST THE SENSOR PAD:
IMPORTANT
• Test your monitor before first use.
• Test your monitor regularly to ensure it is functioning correctly.
• Test your monitor every time you move the Sensor Pad to a different place.
MOVEMENT ALARM
• Alarm activates when no
movement is detected by the
Sensor Pad for 20 seconds.
• Both the Parent Unit and the
Camera speakers will emit
warning sound.
• Movement Alarm icon will show
on the LCD screen.
2.3 - PAUSING AND RESTARTING THE SENSOR PAD
Allows you to pause the Sensor Pad if you remove baby from the cot, e.g. for feeding or
comforting.
Pause Sensor Pad
IMPORTANT
• If you do not pause the Sensor Pad, the alarm will sound if there is no movement after
20 seconds.
• Ensure to unpause the Sensor Pad before putting baby in the cot.
2.4 - ADJUST THE SENSOR PAD SENSITIVITY LEVEL
To ensure adequate monitoring of your child's movements, you can adjust the sensitivity of the
Sensor Pad in the main settings menu. Set a high sensitivity for a newborn and a lower sensitivity
as the child grows and gains weight. A thicker mattress will also need a higher sensitivity.
8
All manuals and user guides at all-guides.com
1) After activating the Sensor Pad, the alarm
should go OFF after 20 seconds.
2) Rub you hand over the mattress and confirm
the alarm stops.
18°C
IF THE ALARM DOES NOT SOUND
• Avoid contact with the cot while
Sensor Pad is in operation.
• Place the cot near a supporting wall to
reduce vibrations.
• Adjust the Sensor Pad sensitivity level.
• Turn OFF cot mobile, fans, loud music
or anything else that may cause
vibration.
1) From the Camera, press the
Pause button on the top right
of the unit.
OR
From the Parent Unit, tap the
screen and tap the Sensor Pad
Pause icon
in the upper left
corner of the display.