IGNITION
Open the gas cock, and set the desired temperature on the boiler thermostat.
The control box will go into self-testing mode, after which the burner will ignite automatically. Should it not
ignite and the "blocking" button light up, then press the latter so that the self-testing procedure is repeated.

PROLONGED DISUSE

Should the burner not be used for a lengthy period of time, close the gas cock and disconnect the mains
supply at the main switch.
MAINTENANCE
Have a qualified technician carry out the following operations once a year:
● check the valves' internal seals;
● clean the filter;
● clean the fan and the combustion head;
● check the position of the ignition electrode tips and the position of the control electrode;
● check the setting of gas and air pressure switches;
● check combustion, taking readings of CO
and CO emissions and of FLUE GAS TEMPERATURE;
2
● check all seals.