Technical Data; Spare Parts - Hansgrohe Sportive 32400000 Instrucción De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and cold
water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water,
swivel to the right = cold water.
32400000/32401000: The flow is changed from
bath to shower function by pulling the knop at the upper
side of the spout. After shutting off the water flow, the
mixer returns automatically to the bath function.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G ½":
Rate of flow 3 bares:
back flow and vacuum breaker
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't
work
6
English
To adjust the hot water limiter on single lever mixers,
please see page 15.
No adjustment is necessary when using a continuous
flow water heater.
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 1.5 bars.

Spare parts

1
1.1 screw cover
2
3
4
5
6
7
8
9
max. 10 bars
10
1 - 5 bars
16 bars
max. 80° C
65° C
150 ± 16 mm
cold right - hot left
approx. 22 l/min
Cause
-
Shower filter seal dirty
-
Filters dirty
-
Non return ralve didn't move
back
- Cartridge defective
- Cartridge defective
Sedimentation
- Hot water limiter incor-rectly set
-
Flow limiter in handshower isn't
removed
-
Filter are dirty
-
Non return ralve didn't move
back
handle
flange
nut
cartridge cpl.
escutcheon
S - unions
aerator cpl.
selector
diverter knob
non return valve
Remedy
-
Clean filter seal be-tween
shower and hose
-
Clean the fil-ter/exchange filter
-
Exchange non return valves
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
-
Remove flow limiter
-
Clean the fil-ter/exchange filter
-
Exchange non return valves
32091000
94191000
94192000
94194000
92730000
94135000
94140000
13956000
94077000
94078000
94074000

Publicidad