Data Management - resideo Braukmann VM242A Instrucciones De Instalación

Ordenador portátil para medición de flujo
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operation
Highlight option to be changed
Enter data field
Cursor appears at first digit
Change value
Move cursor to next digit to be
changed
Change value
etc., when done:
Move cursor until it disappears
to save the value
5.7 DP Measurement
Used to display differential pressure not linked to a kv-value.
If only one hose is connected static pressure is shown.
Data shown on screen:
Large centered figure: actual differential pressure
T
– temperature measured over temperature sensor
1
connected to port T
11
T
– temperature measured over temperature sensor
2
connected to port T
22
T
-
– temperature difference between T
1
2
T
– internal device temperature
Int
The following commands are available:
Operation
Return to main menu
Zoom
Zero calibration
Digits are enlarged when "Zoom" is pressed. To return to
normal size press "Zoom" for longer than one second.
5.8 USB Data Exchange
Used to activate device for data exchange with PC over USB
cable supplied. BasicMes-2 software has to be installed to up-
and download data to and from device.
Operation
Return to main screen without
activating data exchange
Activate data exchange
5.9 Print
Used to print measuring results over optional pocket printer
(OS-No. VMA241A001).
MU2H-2323GE25 R0620
Command Key
UP/
È
DOWN
ON
Æ
UP/
È
DOWN
ON
Æ
UP/
È
DOWN
ON
Æ
(optional)
(optional)
and T
1
2
Command Key
RETURN
ESC
ZOOM
UP/
DOWN
PD = 0
ON
Command Key
ESC
ESC
ON
ON
GB
Operation
Return to main menu without
printing or after printing
View printout on the screen
Send data to printer
Data is sent via infrared port to printer. Ensure that printer is
switched on and infrared receiver on printer is in direct line of
sight with the BasicMes-2.
Only tagged data is printed
5.10 Save Measurements
Used to save measurements under a project. A project file
can be created with the BasicMes-2 in the field or with the PC
software supplied with the BasicMes-2 and then uploaded
onto the device.
How to assign a measurement to a project:
Operation
Highlight project
Select project
Highlight riser
Assign measurement to riser
Information screen appears
Confirm notification
If a measurement has already been assigned to the riser a
confirmation screen appears
Do not overwrite old data
Device returns to riser selection screen
Overwrite old data
Information screen appears
Confirm notification
Device returns to main menu

5.11 Data management

Used for following functions:
Menu item
Print protocol
Delete riser
Delete project
Delete all projects
9
Command Key
ESC
ESC
UP/
È
DOWN
PRINT
ON
Command Key
UP/
È
DOWN
OK
ON
UP/
È
DOWN
OK
ON
OK
ON
ON
ESC
YES
ON
OK
ON
Purpose
Print measurements saved
within a project over
optional pocket printer
Delete single riser of a
project
Delete complete project
Delete all projects stored in
device

Publicidad

Tabla de contenido
loading