Continuous Drainage - EDM Product 07688 Manual Del Usuario

Desumidificador de toque suave
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Ref. 07688
DRAINING INSTRUCTION
Draining water can storage in the water tank, or be continuous drained by PVC tube. (The PVC tube is not
included in the product.)
USAGE OF WATER TANK
- When dehumidifying, the condensing water may be drained to water tank.
The unit stops working and illuminates the indicating when the water tank
is full of water. Please pour out the water that time.
- Fig 01 Take out the water tank as Fig 01 and pour out the water.
- Put the water tank back.
- Press power key to turn on the unit.

CONTINUOUS DRAINAGE

- Before continuous draining water, please take out the water tank and plug a
draining tube to draining hole (See Fig 02.) Then put the water tank back.
- Fig 02 Draining tube should place lower than the draining hole to let water
flow out.
Attention:
- The desired tube: inner diameter 10mm / outer diameter 12mm max.
- After assembling tube, please ensure the water tank is placed back, otherwise
the product will not work.
FILTER REMOVAL
- Take out the water tank before remove the filter.
- Pulling out the filter with handles of filter.
Wash the filter with cool water (cooler than 40ºC) every two weeks, and
put filter back after it air-dried naturally.
MAINTENANCE INSTRUCTION
- The unit is not allowed to be placed on surface which is soft or not flat to avoid the unit cause noise, vibra-
tion, and water or electricity leakage when operating.
- Never insert any slim rod or hard stuff into the unit to avoid the damage of the unit.
- Please disconnect the power cord to the power supply when you turn off the unit or intend to stop using for
long time.
- In order to improve the performance of dehumidifier, please keep the unit in open place away from barriers
which may block the air.
- Please wash the filter with cool water (cooler than 40ºC) every two weeks, and put filter back after it
air-dried naturally. (Note: Never use gasoline or alcohol to wash the filter.)
TROUBLESHOOTING
1) Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure
that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
2) Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or
vapour being present while the work is being performed.
3) Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being
used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
4) Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire
extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to
INSTRUÇÕES IMPORTANTES DE SEGURANÇA / IMPORTANT SAFETY INSTRUCTIONS
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
(Fig 01)
(Fig 02)

Publicidad

Tabla de contenido
loading

Tabla de contenido