 The Skip Function only intervenes until it reaches the subsequent programmed 
switching point. At this point the Skip Function is cancelled and the programmed 
switching cycles are activated once again. 
Programming Errors  
 
If "EEE" appears, there is a setting error. The number of the switching cycle with the error 
is displayed.  
Move the setting switch to P.  
Press  the  button  until  it  displays  the  cycle  with  the  error.  Correct  it  and  then  move  the 
setting switch to "RUN" to exit the programming mode.  
Every switch‐on point is linked to the subsequent switch‐off point. Therefore the following 
ON/OFF combinations can, for example, lead to errors. 
Possible causes of errors: 
 
Activation ON 
a) 
Programmed switch‐on 
b) 
No setting 
c) 
Day block (e.g. 1, 2, 3, 4, 5) 
d) 
Day block 
e) 
Programmed time activation 
(e.g. Wednesday, 09:00) 
f) 
Switch on and off set at same times (e.g. Wednesday, 09:00) 
 
Technical Data of programmer 
 
 Daily and weekly programming of 16 switches per channel (8 x ON, 8 x OFF). With day 
block programming, there are 56 switch possibilities.  
 The minimum time interval between switching points is 1 minute. 
 Lithium battery (3Vdc) lasting up to 5 years without power supply.  
 Ambient temperature: ‐10°C to +55°C (T‐10; T55). 
 
 
 
 
 
 
Deactivation OFF 
No setting 
Programmed deactivation 
Different day block (e.g. 1, 2, 3, 4, 5,6) 
Day of the week 
Deactivation  of  the  set  time  is  prior  to  the 
activation  time  on  the  same  day  (e.g. 
Wednesday, 08:59) 
15 
ENGLISH