DT1100
OWNER'S MANUAL
Thank you for purchasing
the DynaTrap
insect trap!
®
This product may be covered by one or more U.S. patents
or pending patent applications. See www.DynaTrap.com/patents
IMPORTANT: READ CAREFULLY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING:
when using electric appliances, basic precautions should
always be followed, including the following:
1. Please read all instructions before using the DynaTrap
Insect Trap and keep for future reference.
®
2. Always turn unit off and disconnect plug before servicing or cleaning.
3. To reduce the risk of injury from moving parts or electric shock, always turn unit off and disconnect plug when
not in use and before servicing or cleaning.
4. Always unplug before replacing lamp. Replace with same type rated 7-Watt bulbs, DynaTrap
5. Do not position the unit near heat, gas, oil or other flammable materials.
6. Place out of reach from children.
7. To reduce the risk of electrical shock, do not put appliance in water or other liquid.
8. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or if it has been dropped into water or other liquid.
9. Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
10. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
12. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
13. Do not touch fan while in motion.
14. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle.
Keep cord away from sharp edges.
15. If using outdoors, use only extension cords with a tag stating, "Suitable for Use with Outdoor Appliances."
16. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
17. Only use attachments recommended or sold by the manufacturer.
18. This appliance is provided with double insulation. Use only identical replacement parts.
See instructions for Servicing Double-Insulated Appliances.
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit. Save carton for off-season storage (if needed).
2. If hanging or mounting the trap place approximately 3–6 feet above the floor/ground level for optimal catch
rate and easy access for cleaning.
3. If mounting the trap to a wall, secure the mounting bracket to a wall, fence, or other stationary surface using four
(4) screws. Then, mount the trap on the bracket by sliding the mounting channel on the side wall of the trap over the
mounting bracket peg.
4. For best catch results leave unit on at all times, except when cleaning or servicing.
5. Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from
competing light sources.
6. It is recommended to place the unit at least 20 to 40 feet away from where people will be sitting.
7. This unit is all-weather resistant - designed for outdoor use including rainy conditions.
Intended for household and commercial, indoor and outdoor use.
8. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other).
This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug.
If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
9. SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of insulation are
provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a
means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme care
and knowledge of the system and should be done only by qualified service personnel. Replacement parts for a
double-insulated appliance must be identical to those parts in the appliance. The symbol must be identical to those
parts in the appliance. A double-insulated appliance is marked with the words "DOUBLE INSULATION",
"DOUBLE-INSULATED" or the symbol:
FCC COMPLIANCE
This device complies with part 18 of the FCC rules. This product may cause interference to radio equipment and should not be installed
near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30
MHz. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
USER MAINTENANCE INSTRUCTIONS - CLEANING
Clean the trap at least once a week to prolong life of the unit, insure fire prevention, and provide for more efficient operation.
1. Be sure to clean the unit once per week.
2. Unplug before cleaning.
3. For weekly cleaning, twist the cage clockwise, and remove the damper by grasping the crossbar near the edge of the damper.
Pull up firmly. Remove any buildup from the inside of the retaining cage and fan with a brush. Replace damper, snap firmly
into place.
4. For major cleaning, remove the screws securing the fan housing to the light housing. After removing the screws, gently pull
the fan housing away from the light housing. Using a soft brush, remove dirt and debris from the light housing. Once the
cleaning process has been completed, align the screw holes in the fan housing with the screw holes in the lighting unit and
model 41050.
®
tighten the screws to the base of the lighting unit.
5. When replacing the retaining cage – DO NOT press / push against the screen windows.
REPLACING BULB Replace With DynaTrap Bulb #41050
The Light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure
optimal UV effectiveness. Even though the bulb's light may be visible to you, its ability to attract insects diminishes over time.
1. UNPLUG UNIT, and allow bulb to cool before replacing.
2. Remove screw (A). Twist cover counter-clockwise (B). Tilt cover back to expose bulb (C). Note: Upper and lower sections
will remain connected by electrical wire - Do Not Pull or Attempt To Disconnect.
3. Untighten the screw securing the base of the light bulb to the light housing. Slide the metal clip to the side. Cover the
bulb with a cloth to protect your finger and hand. Grasp the bulb (with your hand and fingers protected by the cloth) and
gently pull the bulb from the socket.
4. Remove any debris from the lamp socket with a brush before inserting the new bulb. Replace the metal clip over the
base of the bulb and tighten the retaining screw.
A
REPLACEMENT PARTS
41050
7-Watt Replacement UV Fluorescent Bulb (1 piece)
To see all replacement and accessory parts available for your DynaTrap visit www.DynaTrap.com.
HOW THE DYNATRAP
INSECT TRAP WORKS
Flying insects are attracted to the unit by UV light and
CO2 that is generated by the photo-catalysis between
the UV lamps and special TiO2 coating. The fan then
pulls the insects into the screened base, trapping
them until they dehydrate and die. The base can be
removed, allowing the contents to be periodically
emptied into the trash.
TROUBLESHOOTING
Problem:
Bulb does not illuminate
and fan does not spin.
Bulb illuminates, but fan
does not spin.
Fan spins, but bulb does
not illuminate.
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This
warranty is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain
your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or
abuse. If this unit has been altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the
United States, excluding Canada and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential,
or any other damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states
do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
SAVE THESE INSTRUCTIONS
C
B
Dynamic Solutions Worldwide, LLC
69 N. Locust St., Lititz, PA 17543
1-877-403-8727 (TRAP)
dynatrap@woodstream.freshdesk.com | www.dynatrap.com
Imported and Distributed in Mexico by:
MARKETING DE MONTERREY, S.A.P.I. DE C.V.
AV. ISIDORO SEPULVEDA No. 565 INT. B, COL. REGIO
PARQUE INDUSTRIAL, APODACA, C.P. 66633,
NUEVO LEÓN | (81) 1090-0210 Ext. 268
RFC: MMO950524R84
© Dynamic Solutions Worldwide, LLC
®
Possible cause:
Correction:
No electrical power.
1. Check plug, receptacle, and fuse or circuit breaker.
2. Check to make sure power is switched to the "ON" position.
Shorted fan.
UNPLUG UNIT: Examine fan to see that it is free from foreign material,
dirt or build-up of dead insects. Clean unit as in "CLEANING" section.
Burnt out bulb.
1. Check all sockets for proper bulb seating and alignment.
2. Replace bulb if needed following instructions under "Replacing Bulb"
FOR HOUSEHOLD AND COMMERCIAL,
INDOOR AND OUTDOOR USE
SEE THE ELECTRICAL SPECIFICATIONS ON YOUR PRODUCT LABEL.
This device complies with Performance Standards for
Light-Emitting Products, 21 CFR, Part 1040, Chapter 1,
Subchapter J, Radiological health.