Whirlpool FM07IDUWA2 Instrucciones Para El Uso página 48

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 108
Select the best location
Location for Installing Indoor Unit
• Where there is no obstacle near the air outlet
and air can be easily blown to every corner of
room.
• Where piping and wall hole can be easily
arranged.
• Observe the required distance from ceiling and
wall according to the installation diagram.
• Where the air filter can easily be removed.
• Keep the unit and remote control 1m or more
from television, radio etc.
• To prevent the effects of a fluorescent lamp,
keep the unit as far as possible from it.
• Do not put anything near the air inlet that could
obstruct it.
• In a place that can bear the weight and will not
increase operating noise and vibrations.
• The indoor unit is not suitable to be installed in
areas used for laundry.
Location for Installing Outdoor Unit
• Install in a convenient and well-ventilated place.
• Avoid installing it where flammable gas could
leak.
• Observe the required distance from the wall
according to the installation diagram.
• The distance between Indoor and outdoor unit
should be 5 meters and can go up to maximum
15 meters with additional refrigerant charge.
• Do not install the outdoor unit in a dirty or
greasy place, near a vulcanization gas exit.
• Avoid installing it at the roadside where it could
be soiled with muddy water.
• A fixed base where operating noise will not
increase.
• Where the air outlet is not obstructed.
• The installation position shall be able to
withstand the weight and vibration of the
outdoor unit and ensure safe installation;
• Where drained water does not become any
problem.
Model
Standard
tubing
Length (m)
FM20ODU
5+5
WA2
FM24ODU
5+5+5
WA2
FM36ODU
5+5+5+5
WA2
Limit of
Limit of Total
Each Indoor
Tubing
Unit Tubing
Lenght (m)
Length (m)
20
40
20
60
25
60
48
Indoor unit
Pipe length is
3~20 meters
Indoor unit
Limit of
Elevation
Difference H
(m)
10
10
10
Pipe length is
3~20 meters
Outdoor unit
Outdoor unit
Extra
refrigerant charge
(g/m)
15 (When total piping
length is over 15m)
15 (When total piping
length is over 20m)
15 (When total piping
length is over 20m)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fm09iduwa2Fm12iduwa2Fm18iduwa2Wa20oduWa24oduWa36odu

Tabla de contenido