BFT SIRIO CBA 230 INV Manual De Instalación página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

x 2
add. start
Add. 2ch
erase 64
language
autoset
Control unit
software version
stat
vers
OK
No total
- +
manoeuvres(in hundreds)
n. cycles
OK
- +
No radio control
devices memorised
n. remotes
OK
- +
List of last 30 errors
err
OK
0---
password
8 -
SIRIO CBA 230 INV
All manuals and user guides at all-guides.com
ACCESS MENUS Fig. 1
See PARAMETERS MENU
See LOGIC MENU
hidden butt
release
desired button
hidden butt
release
desired button
See RADIO MENU
Diagnostics
code
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLOSE input activated
CLS
PED
PED pedestrian input activated
TIME
TIMER input activated
STOP
STOP input activated
PHOT photocell input activated
PHOT
PHOP
PHOT OP opening photocell input activated
PHCL
PHOT CL closing photocell input activated
BAR
BAR safety edge input activated
BAR safety edge input activated on slave motor
BAR 2
(opposite leaves connection)
SWC
SWC motor closing limit switch input activated
SWO
SWO motor opening limit switch input activated
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
SET
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
ER01
Photocell test failed
ER02
Safety edge test failed
bft . . .
ER03
Opening photocell test failed
+/-
ER04
Closing photocell test failed
0000
Safety edge test on slave motor failed (opposite leaves
+/-
ER05
connection)
er06
8k2 safety edge test failed
00
+/-
Board hardware test error
ER1x
*
01.33
Encoder error
ER2x
*
*
02.01
........
ER3x
Reverse due to obstacle - Amperostop
*
ER5x
Communication error with remote devices
30.15
*
+/-
ER7x
Internal system supervision control error.
*
Inverter alarm
ErF3/ F4/F5
ErF1 / F2
limit switch error
*X= 0, 1, .., 9, A, B, C, D, E, F
10--
150-
35. 4 0
DESCRIPTION
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or param-
eter/logic setting
Check photocell connection and/or param-
eter/logic setting
Check safety edge connection and/or param-
eter/logic settings
Check safety edge connection and/or param-
eter/logic settings
-
- Hardware problems with board (contact
technical assistance)
- Motor power or encoder signal cables in-
verted/disconnected.
- Actuator movement is too slow or stopped
with respect to programmed operation.
Check for obstacles in path
Check connection with serial-connected
accessory devices and/or expansion boards
Try switching the board off and back on again
If the problem persists, contact the technical
assistance department.
Check the inverter's connections.
Check the inverter's display for any error
messages
check limit switch connections
 
1520
prg
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
Obstacle threshold
Instantaneous force motor
NOTES
C h e c k
c o n n e c t i o n s
t o
m o t o r

Publicidad

Tabla de contenido
loading

Tabla de contenido