BFT SIRIO CBA 230 INV Manual De Instalación página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Parameter
min.
max.
Default
CLS. S LWD.
1
99
FORCE
BRAKE
0
1
OP SPEED
15
99
CL SPEED
15
50
OP SLOW
15
30
SPEED
CL SLOW
15
30
SPEED
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABELLA "B" - LOGICHE - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
FAST CLS.
Fast closing
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
PRE-ALARM
Pre-alarm
All manuals and user guides at all-guides.com
INSTALLATION MANUAL
Personal
Definition
Leaf/leaves force during
75
closing during slow-down
[%]
1
Braking
99
Opening speed [%]
50
Closing speed [%]
Opening slow-down speed
25
[%]
Closing slow-down speed
25
[%]
Cross out
Default
setting
used
0
Logic not enabled
0
 
1
Switches automatic closing on
0
Logic not enabled
0
 
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
0
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
1
Ped operate with 3-step logic. Pulse
during closing reverses movement.
0
 
Inputs configured as Start E, Start I,
2
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
0
 
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
Description
Force exerted by leaf/leaves during closing at slow-down speed.
This is the percentage of force delivered, beyond the force stored during
the autoset cycle (and subsequently updated), before an obstacle alarm is
generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Enables stopping by injecting direct current in the event the safety edge
is tripped
Percentage of maximum speed that can be reached by motor(s) during
opening.
WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING:
when the display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing.
WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING:
when the display reads "SET", obstacle detection is not active.
Opening speed of motor(s) during slow-down stage, given as a percentage
of maximum running speed.
WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when
the display reads "SET", obstacle detection is not active.
"Closing speed of motor(s) during slow-down stage, given as a percentage
of maximum running speed.
WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when
the display reads "SET", obstacle detection is not active.
Optional extras
CLOSED
DURING
CLOSING
OPEN
CLOSES
DURING
OPENING
AFTER STOP
step-by-step mov.
2 STEP
3 STEP
4 STEP
OPENS
OPENS
OPENS
STOPS
CLOSES
CLOSES
STOP + TCA STOP + TCA
OPENS
OPENS
OPENS
13
-