3.5.3. Resetting the Overheat Protector
The sensor box contains a temperature sensor and
an overheat protector. If the temperature in the
sensor's environment rises too high, the overheat
protector cuts off the heater power. Resetting the
overheat protector is shown in figure 14.
Note! The reason for the going off must be deter-
mined before the button is pressed.
3.6. Electric heater insulation resistance
When performing the final inspection of the electrical
installations, a "leakage" may be detected when
measuring the heater's insulation resistance. The
reason for this is that the insulating material of the
heating resistors has absorbed moisture from the
air (storage transport). After operating the heater
for a few times, the moisture will be removed from
the resistors.
Do not connect the power feed for the heater
through the RCD (residual current device)!
Figure 14.
Reset button for overheating limiter
Abbildung 14. Rücksetzknopf des Überhitzungsschutzes
DE
3.5.3. Zurückstellen der Überhitzungsschutzes
Das Fühlergehäuse enthält einen Temperaturfühler
und einen Überhitzungsschutz. Wenn die Temperatur
in der Umgebung des Temperaturfühlers zu stark
ansteigt, unterbricht der Überhitzungsschutz die
Stromzufuhr. Das Zurücksetzen des Überhitzungs-
schutzes wird in Abbildung 14 dargstellt.
Achtung! Bevor Sie den Knopf drücken, müssen
Sie die Ursache für die Auslösung des Überhitzungs-
schutzes ermitteln.
3.6. Isolationswiderstand des Elektrosaunaofens
Bei der Endkontrolle der Elektroinstallationen kann bei
der Messung des Isolationswiderstandes ein "Leck"
auftreten, was darauf zurückzuführen ist, daß Feuch-
tigkeit aus der Luft in das Isolationsmaterial der
Heizwiderstände eingetreten ist (bei Lagerung und
Transport). Die Feuchtigkeit entweicht aus den Wi-
derständen nach zwei Erwärmungen.
Schalten Sie den Netzstrom des Elektrosaunaofens
nicht über den Fehlerstromschutzschalter ein!
39