Maintenance - Dometic AH-Elite Control Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73

Maintenance

No.
Description
P-22
Voltage calibration
P-23
Set point temperature
3
differential
P-24
Moisture mode mini-
mum temperature
P-25
Auto fan speed temper-
ature differential
P-26
Supply air high
temperature limit
1
This feature is only available in software revision A15 and newer.
2
This feature is only available in software revision A16 and newer.
3
This feature is only available in software revision B23 and newer.
4
This feature is only available in software revision B24 and newer.
5
Setting increments have to be entered in °F even if the P-10 setting has been
changed to °C.
10
Maintenance
Return-air filter
Check the return-air filter about once a month and clean as necessary. To clean the
filter, remove it from the unit, rinse with water, air dry and reinstall.
22
Defaults
Factory
AC
voltage
2
50 °F
3
(10 °C)
2 °F
4
(1.1 °C)
OFF
4
Range
Custom
Adjust to match the accurate volt-
age reading.
1 = 1 °F (0.55 °C) differential
2 = 2 °F (1.1 °C) differential
40 – 75 °F (4.4 – 23.9 °C)
1 °F – 3 °F (0.55 °C – 1.67 °C)
OFF
95 °F – 140 °F (35 °C – 60 °C) in
5-degree steps
AH-Elite Control
5
5
5
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido