Thank you for purchasing our smoke alarm device.
Please take a few minutes to read the user's manual thoroughly and familiarize yourself and your
family with its operation.
And save it for future reference.
PRODUCT SPECIFICATIONS
• POWER: built-in DC3V (CR123A) Lithium battery
(battery not replaceable)
• OPERATION CURRENT: <8uA (standby), <70mA (alarm)
• ALARM VOLUME: >85dB(A) at 3 meters.
• ALARM SENSITIVITY: 0.11-0.16dB/m
• SILENCE TIME: approx. 10 minutes
• SMOKE ALARM DEVICE SOUND PATTERN:
BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s – BI 0.5s – pause 1.5s,
with the red LED flash, repeat this alarm pattern.
• COMPLY WITH: EN14604:2005/AC-2008
DESCRIPTION
The unit is a photoelectric smoke alarm device.
With the photoelectric technology, it is more sensitive to detecting slow smolder fires which
general thick, black smoke, a little heat and may smolder for hours before bursting into flames.
The smoke alarm device does not contain the radioactive material which is harmless to the
environment.
The smoke alarm device should be installed in every room (except the bathroom and
kitchen), and every other area of the home, making sure the people in the home will be
able to hear and respond to the alarm sound.
For minimum protection, you should fit an alarm respectively for the hallways, living room,
bedrooms and child rooms, each unit shall be placed in the middle of the ceiling of each
room to protect.
Typical single storey dwelling with recommended:
Install a smoke alarm device on the ceiling or wall inside each bedroom and in the hallway
outside each separate sleeping area.
If a bedroom area hallway is more than 30 feet long, install a smoke alarm device at each end.
If there is a basement: install a smoke alarm device on the basement ceiling at the bottom
of the stairwell.
Typical multi-storey dwelling with recommended protection:
Install a smoke alarm device on the ceiling or wall inside each bedroom and in the hallway
outside each separate sleeping area.
If a bedroom area hallway is more than 30 feet long, install a smoke alarm device at each
end install a smoke alarm device at the top of a first – to- second floor stairwell.