CONDOR 500 - connection diagram of the motors
• DELAY OF THE MOTOR n.2
1
• DELAY OF THE MOTOR n.1
1
Configuration - MOTOR n.1 ON THE LEFT, MOTOR n.2 ON THE RIGHT
MOTOR n.1 (on the left)
OPEN with OP1
COMMON on CM1
CLOSED on CL1
CN1
12
COMUNELLO ®Copyright 2014 - All right reserved
SW1
SW2
ON
ON
1
2
1
2
2
DELAY
INV
INV
MOTORS
MOT.2
OFF
MOT.2
SW1
SW2
ON
ON
1
2
1
2
2
INV
INV
DELAY
OFF
MOT.2
MOTORS
MOT.1
MOTOR n.2 (on the right)
OPEN with OP2
COMMON on CM2
CLOSED on CL2
2