Changing the radio key
Systems with only BE1481 Smoke alarms
Step 1: Change the radio key on the BE1481 Smoke alarm
1
Remove one of the batteries to turn off the smoke alarm and wait at least 30 s.
Press and hold the test button as you insert the battery again and continue holding
it until the status LED goes from slow to rapid flashes. Release the button to enter the
programming mode.
2
The smoke alarm is reset to radio key 0 and the status LED lights up to confirm.
3
Within 4
s, press and hold the test button until the LED goes out to select the next
radio key. Radio key 1 is now selected and the status LED lights up to confirm.
Follow this procedure to advance to the next radio key. There are 9 radio keys
available. If you continue beyond radio key 9, the unit will reset to radio key 0.
4
After 4 s, the smoke alarm automatically exits the programming mode and the LED
goes out to confirm.
Follow the above steps to change the radio key on all BE1481 smoke alarms in your
system. All Visit units must be set to the radio key to operate as a group.
1
Flashes
Don't release the button until
Radio key 0 is selected. The
the LED flashes rapidly.
LED lights up to confirm.
14
2
3
Lights up
Goes out
Press and hold until the LED goes
out to select the next radio key.
Step 2: Change the radio key on the receiver
1
Press and hold the test/function button on the receiver until the green and yellow Visit
LEDs blink alternately. Release the button.
2
Press the test button on any transmitter within 25 s to transmit the new radio key.
3
All Visit LEDs on the receiver blink 5 times to show that the radio key has
been changed.
1
2
3
EN
15