The transformer must be able to supply 70VA for each led lamp connected. For example, if you want to control 4 lamps, you must connect
them in parallel to a transformer of at least 280VA. The pushbutton must be able to withhold the power consumed by the number of lamps
installed.

5.1.2. Operation modes

The COLORPLUS ECO unit enables different light scenarios to be created inside the swimming pool with two operation possibilities:
Set colour: Selection of one set colour out of seven possibilities.
Automatic sequence of colours: Selection of seven colour sequence programmes. Each programme is defined by the lighting time of each colour
and the transition time from one colour to another according to the following table:
SEQUENCE
The colour or sequence is changed by pressing the pushbutton. The colour and sequence cycle is rotary. For example, if you are in colour 6, by
pressing once, you will reach colour 7. If you press once again, you will go to sequence 1. If you are in sequence 7, press once and you will get
to colour 2, which is Red.
Colour 1, corresponds to white and is reached by one long press.
5.2. COLORPLUS TOP: Modulator control and/or Remote control
The system has 20 operation modes: 12 set colours and 8 sequences of different colours (see section 5.2.2.).
The Modulator controls switching the lamps on and off, changes of colour and sequences and switching off timing.
If you have a remote control, apart from the modulator operations, you can also switch colours of a sequence on and off and select the switching
off time.
5.2.1. Electrical connection diagram
For correct installation, you will need the Modulator, the transformer and finally the leds lamp. As an option, this system can be controlled by
Remote Control.
The Modulator is connected to the 230 V~ac mains by means of two terminals indicated MAINS, and to the primary input of the transformer
(230 V~ac) by means of the terminals indicated TRF (See attached diagram).
Each Modulator, it can control until a maximum of five spotlights.
The transformer must have the capacity to supply 70 VA to each led lamp connected. For example, if you want to control 4 lamps, they should
be connected in parallel to a transformer of at least 280VA.
Each Modulator can control up to a maximum of 12 LED spotlights.
Once the unit is connected, proceed as follows to start-up the projector for the first time:
• Switch on the unit by activating the 230 V~ac. at the input of the Modulator, which will automatically syntonize with the transformer. The
green led of the Modulator will flash every 2 seconds and the lamp will remain off.
All manuals and user guides at all-guides.com
COLOUR Nº
1
2
3
4
5
6
7
1
Red
Blue
2
Red
Green
3
Purple
Cyan
4
Red
Blue
5
Purple
Cyan
6
Yellow
Purple
7
Green
Red
COLOUR
White
Red
Blue
Green
Purple
Cyan
Yellow
ORDER OF COLOURS
Green
Purple
Cyan
Cyan
Blue
Purple
Yellow
-
-
Green
-
-
Yellow
-
-
Cyan
-
-
Blue
-
-
3
Yellow
Yellow
-
-
-
-
-