Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5
m length on the wall, making sure that the bob can swing freely. Switch on the
device and align the vertical laser to the plumb line. The precision is within the
specified tolerance if the deviation between the laser line and the plumb line is
not greater than ± 1.5 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the wall.
Turn the laser cross approx. 2.5 m to the right and
mark point C. Check whether the horizontal line
from point C is level with point B to within ± 2 mm. Repeat the process by
turning the laser to the left.
!
Regularly check the adjustment before use, after transport and after
extended periods of storage.
Technical data
Self-levelling range
Precision
Laser wavelength linelaser (green)
Laser wavelength plumb laser (red)
Laser class / line laser output power
Laser class / plumb laser output power
Power supply
Battery operating time (all lasers on)
Battery recharging time
Operating temperature
Storage temperature
Weight (incl. rechargeable battery)
Dimensions (W x H x D)
(Subject to technical alterations 04.15)
PowerCross-Laser 5G DLD
± 2°
± 1.5 mm / 10 m
510 nm
650 nm
2M / < 5 mW
2 / ≤ 1 mW
Lithium-ion rechargeable battery
approx. 4 h
approx. 4 h
0°C ... + 50°C
-10°C ... + 70°C
1.4 kg
120 x 120 x 200 mm
2,5 m
B
C
GB
17

Publicidad

loading