Note: ISU options available may vary upon the thermostat model and equipment setup.
# ISU
ISU Name
ISU Options (defaults in bold)
120
Schedule Type
No Schedule
MO-SU = Every day the same
MO-FR, SA, SU = 5-1-1 schedule
MO-FR, SA-SU = 5-2 schedule
Each Day = Every day individual
125
Temp Scale
Fahrenheit, Celsius
130
Outdoor Temp
No, Wired, Internet
200
System Type
Conventional Forced Air
Heat Pump
Boiler
Cool Only
205
Equipment Type
Conventional Forced Air Heat:
Standard Gas (STD GAS), High Efficiency Gas (EFF GAS),
Oil, Electric, Fan Coil*
Heat Pump:
Air To Air, Geothermal
Boiler:
Hot Water, Steam
218
Reversing Valve
0/B on Cool, 0/B on Heat
220
Cool Stages
0, 1, 2
(#200=Conv./
200=HP)
221
Heat Stages/Aux/E
Heat Stages: 0, 1, 2
Stages (#200=Conv./
AUX/E Stages: 0, 1
200=HP)
230
Fan Control
Equipment, Thermostat
253
Aux/E Control
Both Aux/E, Either Aux/E
Notes
You can change default MO-FR, SA-SU schedule here. To edit periods during days, temperature setpoints, or to
turn Schedule On/Off, from the home screen, go to MENU/SCHEDULE.
Select outdoor temperature data source. This ISU automatically defaults to Internet when registered to
Honeywell Home app and no wired outdoor sensor is selected. We recommend using a wired outdoor sensor
connected to the "S" terminals on the UWP. (See "Wiring" on page 6.)
An outdoor temperature is required to set the following ISUs: ISU 355 Compressor Lockout, ISU 356 Aux
Heat Lockout, ISU 1013 Low Outdoor Temperature Ventilation Lockout, ISU 1014 High Outdoor Temperature
Ventilation Lockout, and ISU 1015 High Outdoor Dew Point Ventilation Lockout.
Basic selection of system your thermostat will control.
This option selects the equipment type your thermostat will control. Note: This option is NOT displayed if ISU
200 is set to Cool Only.
*Fan coil setting is for a residential application with a hot water coil in an air-handler.
This ISU is only displayed if ISU 200 is set to Heat Pump. Select whether reversing valve O/B should energize
on cool or on heat
Only 1 compressor stage available on TH6220WF model if configured for heat pump.
Maximum of 2 Heat Stages for conventional systems. Maximum of 1 Aux/E stages for heat pump systems.
This ISU is only displayed if ISU 205 is set to Electric Forced Air or Fan Coil.
Set "EITHER AUX/E" if you want to setup and control Auxiliary and Emergency heating separately . This ISU is
only displayed if ISU 200 is set to Heat Pump AND if ISU 221 Aux/E stages = 1.
Note: This ISU available on TH6320 model only.