Be sure the electrical system of your pool conforms with the following requirements
of the Canadian Electrical Code (CE), and all local codes and ordinances. A licensed
or certified electrician must install the electrical system to meet or exceed those
requirements before the light and (fixture-housing) is installed. Some of the CE
requirements are listed below.
The junction/deck box must be sealed to the conduit to prevent water from
getting into the box, see Figure 1, below.
The niche must be properly installed so the center line of the Underwater Light's
lens is at a maximum depth of 600 mm below the surface of the water in the
pool, see Figure 2 on page 8.
The following information is for the Junction Box and pool deck location for Canada only.
Junction/Deck boxes shall be installed:
(a) above the normal water level of the pool;
(b) so that the top of the box is located at or above the finished level of the pool deck;
(c) in such a manner or location that the box will not be an obstacle; and
(d) in such a manner that any water on the deck will drain away from the box
(See diagram below).
Deck water drains
away from Junction/Deck Box
Approved Junction/Deck Box
Top of Junction Box Flush
with Deck
Figure 1, Canada.
®
LIGHT FIXTURE INSTALLATION
(NEW POOL CONSTRUCTION - CANADA)
Water level
below Junction/Deck Box
GloBrite Color Changing LED Pool/Spa Light Installation and User's Guide
Approved Junction/Deck Box
elevated and protected
Junction/Desk Box elevated above
Deck and Protected
Diving Board or
other equipment
to protect
Junction/Deck Box