Pentair 320 Serie Manual De Instrucciones página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

HI F L O F E E DE R K IT # R 1 7 1 0 9 9
FOR MODELS #320 & #322
DIRECTIONS
1. Turn off pump and timer switches.
2. Loosen compression nut and remove Feeder tube and 90° elbow from the diverter tee at base
of Feeder.
3. Using thread seal tape as thread sealant, wrap ½" MPT plug threads (1) with several turns of the tape only.
Install in place place of 90° elbow on diverter tee.
4. Disconnect other end of Feeder tube from control valve 90° elbow, by loosening compression nut. Use the compression
nuts from old tube to attach new 6' section (2).
5. Push compression nut over tubing end, then push tubing onto tapered end of elbow. Tighten nut firmly by hand.
6. Connect other end of plumbing. IF POOL/SPA HAS A HEATER, INSTALL BETWEEN FILTER AND HEATER. IF
YOUR POOL/SPA HAS A SOLAR SYSTEM, INSTALL BEFORE SOLAR
SYSTEM INLET LINE. IF NO HEATER, INSTALL BETWEEN PUMP AND FILTER. Drill
burrs, and install saddle clamp assembly. (See illustration) Tighten clamp with screwdriver. Slide small stainless steel
clamp #3 over tubing #2 and slide tubing over saddle tube fitting #4. Secure tubing to fitting by tightening camp with
screwdriver. Make sure clamp is below rib at end of saddle tube fitting.
7. To install ½" CHECK VALVE, cut tube approximately 6" away from plumbing connection. Remove compression nuts
from check valve. Slide nuts over both ends of tube. Insert check valve ends into both pieces of tubing and tighten
compression nuts firmly by hand. Be sure arrow "FLOW" is pointing toward the Feeder.
HI FLO FEEDER KIT #R171099
PARTS BREAKDOWN DRAWING
Item Quantity
Part No.
Description
1
1
R172134 Plug, ½" MPT
2
6
R172093 Tube, ½" ID Chlorinator
ft
3
1
R175013 Clamp, S.S. Tubing
4
1
R171162 Fitting, Saddle Tube
5
1
R172263 Gasket, Saddle
6
1
R172264 Clamp, Saddle
7
1
R172324 Valve, ½" Tube check
/
9
16
NOTE:
When using this kit with a pool/spa
combination (to prevent draining spa)
shut off Feeder control valve when only
the spa is in use.
Technical Support: (800) 831-7133
/
" hole in plumbing, remove
9
16
" Hole in Plumbing
R24079-1200