Electric heater Aqua spa
IInstallation example 2: Bubble pool
Ver. 1: Pahlén's recommendation.
1
Ver. 2:
In case of space shortage
Ø50
Ø50
L>200
L>200
Installation example 3: Hot tub
3
Installation SPA-elvärmare/bubbelpool
3
6
5
Installation SPA-elvärmare/badtunna
Installation SPA-elvärmare/badtunna
1
4
7
4
Belysning
7
Ø50
Ø50
L>200
L>200
9
Belysning
2
5
Ø50
Ø50
L>200
L>200
8
ENGLISH
NOTE!
Electric heater must
always be positioned at
least 200 mm below the
water level.
1. Overflow run
8
2. Expansion tank
3. Bottom drain outlet
4. Inlet
5. Pump
6. Filter
7. Electric heater
8. Check valve
9. Drain
Drawing no: M12363-0
2017-05-31 ASA
NOTE!
Electric heater must
always be positioned at
least 200 mm below the
water level.
6
1. Bottom drain outlet
2. Inlet
3. Pump
4. Filter
5. Electric heater
6. Check valve
7. Drain
Drawing no: M12756-0