Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified
repair establishment or individual with original or equivalent
parts. Warranty and recall repairs must be performed by an
authorized service center; please contact customer service
for assistance.
WARNING:
Before inspecting, cleaning or servicing the machine, shut
off engine, wait for all moving parts to stop, and discon-
nect spark plug wire and move it away from spark plug.
Allow 30 minutes of cool down time before performing
any maintenance. Failure to follow these instructions
can result in serious personal injury or property damage.
WARNING:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes resulting in possible
serious injury.
WARNING:
When servicing, use only recommended or equivalent
replacement parts. Use of any other parts could create
a hazard or cause product damage.
NOTICE:
This product is not equipped with a spark arrestor and
cannot be used on U.S. forest lands; in addition, product
users must comply with Federal, State, and local fire pre-
vention regulations. Check with appropriate authorities.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts, caps,
etc. Tighten securely all fasteners and caps and do not
operate this product until all missing or damaged parts
are replaced. Please contact customer service or a quali-
fied service center for assistance.
MAINTENANCE
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or de-
stroy plastic which could result in serious personal injury.
Before running the engine, perform the following pre-
operation steps:
Check that all bolts, nuts, etc., are securely tightened.
Make sure the air filter is clean.
Check both the engine lubricant level and the fuel tank
level; refill as needed.
Inspect the work area for hazards.
If there is excessive noise or vibration, stop the unit
immediately.
NOZZLE MAINTENANCE
See Figure 21.
Excessive pump pressure (a pulsing sensation felt while
squeezing the trigger) may be the result of a clogged or
dirty nozzle.
Turn off the pressure washer and shut off the water sup-
ply. Pull trigger to release water pressure.
Remove the nozzle from the spray wand.
WARNING:
NEVER remove nozzles without first turning off the
engine, and locking the lock out on the trigger handle.
NEVER point the nozzle at your face or at others. The
quick-connect feature contains small springs that could
eject the nozzle with some force. Failure to follow these
instructions could result in an eye injury or other serious
personal injury.
To free any foreign materials clogging or restricting the
nozzle, blow out or remove debris with a straightened
paper clip or fine needle (not included).
Using a garden hose, flush debris out of nozzle by back
flushing (running the water through the nozzle backwards
or from the outside to the inside).
Reconnect the nozzle to the spray wand.
Turn on the water supply and start the engine.
Page 14 — English