Descargar Imprimir esta página

Publicidad

Enlaces rápidos

MINI-EH
Specifications
Communication protocol :
Protocol programming :
Proximity reading type :
Operating frequency:
Reading distance :
Green LED :
Red LED :
Orange LED :
Buzzer ON/OFF:
Backlight ON/OFF:
Tamper protection :
Cable distance:
Consumption :
Power Supply:
Panel Connection:
IP Rating :
Mounting :
Housing :
Resin potted electronic :
Dimensions (mm) :
Specifiche
Protocollo di comunicazione:
Programmazione protocollo:
Tipo di lettura di prossimità:
Frequenza operativa:
Distanza di lettura:
LED verde:
LED rosso:
LED arancione:
Cicalino ON/OFF:
Retroilluminazione ON/OFF:
Protezione allarme:
Distanza cavo:
Assorbimento:
Alimentazione:
Connessione del pannello:
Classe IP:
Montaggio:
Alloggiamento:
Elettronica incapsulata in resina:
Dimensioni (mm):
USER MANUAL
Wiegand 26, 34, 37, 42, 24, 32, 35,
40bit (default: Wiegand26bit)
By Dipswitch
EM 4002/4100 compatible and
HID (125kHZ) compatible
125 Khz
up to 5 cm
externally controlled
externally controlled
Idle Mode
Yes
Yes
Yes
50 m.
Max. 50mA
9-14V DC
Cable, 0.5 m
IP66
Surface
ABS
Yes
90x51x17
Wiegand a 26, 34, 37, 42, 24, 32, 35,
40 bit (predefinito: Wiegand a 26 bit)
Con dipswitch
EM 4002/4100 compatibile e
HID (125kHz) compatibile
125kHz
fino a 5 cm
controllato esternamente
controllato esternamente
Modalità inattiva
50 m
Max. 50 mA
9-14V DC
Cavo, 0.5 m
IP66
Superficie
ABS
90x51x17
EN
Spécifications
Protocole de communication:
Programmation du protocole:
Type de lecture de proximité:
Fréquence de fonctionnement:
Distance de lecture:
LED vert:
LED rouge:
LED orange:
Avertisseur sonore ACTIVÉ/DÉSACTIVÉ:
Rétroéclairage ACTIVÉ/DÉSACTIVÉ:
Protection anti-sabotage:
Distance de câble:
Consommation:
Alimentation électrique:
Cablâge :
Classe IP:
Montage:
Boîtier:
Éléments électr. moulés en résine:
Dimensions (mm):
IT
Especificación
Protocolo de comunicación:
Programación del protocolo:
Tipo de lectura de proximidad:
Frecuencia operativa:
Distancia de lectura:
LED verde:
LED rojo:
LED naranja:
Buzzer ON/OFF:
Retroiluminado ON/OFF:
Protección contra la manipulación:
Distancia del cable:
Consumo:
Fuente de alimentación:
Conexión del panel:
Clasificación IP:
Montaje:
Carcasa:
Electrónica sellada con resina:
Dimensiones (mm):
FR
EN
IT ES DE NL
Proximity reader
Wiegand 26, 34, 37, 42, 24, 32, 35,
40 bits (défaut : Wiegand 26 bits)
Par dip-switch
EM 4002/4100 compatible et
HID (125kHZ) compatible
125 Khz
jusqu'à 5 cm
contrôle externe
contrôle externe
Mode ralenti
Oui
Oui
Oui
50 m.
Max. 50 mA
9-14 V CC
0.5 m de câble
IP66
Surface
ABS
Oui
90x51x17
Wiegand de 26, 34, 37, 42, 24, 32,
35, 40 bits (predeter.: Wiegand 26)
Por interruptor DIP
EM 4002/4100 compatible y
HID (125kHZ) compatible
125 Khz
hasta 5 cm
controlado externamente
controlado externamente
Modo inactivo
50 m.
Máx. 50 mA
9-14 V CC
Cable, 0.5 m
IP66
Superficie
ABS
90x51x17
FR
ES
1

Publicidad

loading

Resumen de contenidos para XPR Access MINI-EH

  • Página 1 MINI-EH IT ES DE NL Proximity reader USER MANUAL Specifications Spécifications Communication protocol : Wiegand 26, 34, 37, 42, 24, 32, 35, Protocole de communication: Wiegand 26, 34, 37, 42, 24, 32, 35, 40bit (default: Wiegand26bit) 40 bits (défaut : Wiegand 26 bits)
  • Página 2 Specificaties Merkmale Kommunikationsprotokolle: Wiegand 26, 34, 37, 42, 24, 32, 35, 40bit Communicatieprotocol: Wiegand 26, 34, 37, 42, 24, 32, 35, (Voreinstellung: Wiegand 26bit) 40bit (standaard: Wiegand26bit) Protokoll Programmierung: Mit DIP Schalter Protocolprogrammering: Via dipschakelaar RFID Lesertyp: EM 4002/4100 kompatibel und Naderingsleestype : EM 4002/4100 compatibele en HID (125kHZ) kompatibel...
  • Página 3 WIEGAND Connection/ Connexion/ Connessione/ Conexión/ Anschluss/ Aansluiting Alarm LD22 system LD17 LD18 LD19 LD23 System Busy FUSE2 12Vdc Out Grey- tamp IC15 Free In 1 + Blue- tamp ICN1 IC12 IC11 Free In 1 - Free In 2 + 3 3 6 1 1 1 0 1 3 1 50m.
  • Página 4 Setting a reader to send fixed site code / Réglage d'un lecteur pour l'envoi de code site fixé/ Impostazione di un lettore per l'invio di un codice sito fisso/ Ajuste del lector para el envio del Código Sitio fijo Einstellung des Lesers, einen festen Standortcode zu senden/ Een lezer instellen voor het verzenden van een vaste locatiecode Turn the power OFF.