* BEFORE USING ThIS UNIT
You have just acquired an effective and powerful professional unit.
Take your time to discover how to use it.
1 - Read the instructions carefully
2 - Before using it, charge the unit (photo I. E, page 2)
* OPERaTION qUICK TEST
TESTING YOUR UNIT ON YOUR QUADRICEPS
• Take the electrodes and lightly moisten them with a few drops of water (photo I. A, page 2).
• Connect it to the first channel (match the colours of the connectors, 2 by 2).
• Start the unit using the
key and press the "
" button 6 times.
• Increase power on this channel gradually.
• Once this procedure is done, you can start a program that best suits your needs.
* ThERaPEUTIC aPPLICaTIONS
- Private: to strengthen and / or to maintain muscle strength.
- Physiotherapists: to ease muscular tensions.
- In hospital environment: to prevent muscular atrophy and to treat pain.
I. ChaRGING ThE BaTTERIES
The unit contains rechargeable batteries. Before using it, charge it during 12 hours by connecting it to mains.
Do not use this unit while batteries are charging. When it is not used, charge the batteries for 12 hours every 4 months.
When the batteries are empty, the unit switches to standby automatically, protecting them against untimely discharging.
To charge the unit, connect the charger supplied with the unit (photo I. E, page 2)
bATTERY CHARGE DISPLAY
When the battery is charging, the battery indicator displays
The charging time countdown starts, from
to
.
Once charged, the number
appears in the left angle of the timer pictogram. The battery pictogram displays
When the charging is complete, unplug the adapter from the electrical outlet to insulate electric source.
When the charger is disconnected, the screen switches off.
When the battery indicator is empty
, this means that it is discharged.
II. STaRTING ThE UNIT
STEP 1: DISPLAY - POwER ON
Beware while starting the device ( red button
)
Push briefly (maximum 1 second ) on
.
All pictograms appear and blink for 3 seconds, then the front muscles blink.
If you make a long push, your screen flashes and indicates you the totality of the pictograms which it contains.
To stop the device, push briefly on
.
Or to return in the menu made 2 brief pushes on
.
STEP 2: SELECTING THE MUSCLE zONE(S) TO STIMULATE
Choosing the 1
st
zone :
The screen displays
, meaning you can choose a first muscle zone.
- To choose the front muscles, validate with the "
" key.
- To choose the back muscles, press the
key.
- To return to the front muscles, press the
key.
If you have chosen the front muscles : the 1
muscle zone at the bottom blinks: quadriceps.
st
If you have chosen the back muscles : the 1
muscle zone at the bottom blinks: gastrocnemius (calves)
st
Press the
key to move upwards and scroll the different muscle zones.
To go back, press the
key.
After selecting the muscle group, validate using th "
" key
12
,
, then
to show the current charging status.
.
zone :
Choosing the 2
nd
All pictograms blink and the screen displays
.
The screen proposes to choose a 2
nd
muscle zone :
To choose a 2
nd
muscle zone, validate again either the front muscles or the back muscles, validate "
Choose again another muscle zone, then validate "
".
If you wish one muscle zone only, press the " " key and go to step 3.
The muscle zone(s) selected is (are) displayed.
STEP 3: SELECTING THE PROGRAM
Programs on the left (
SPORT programs ) blink.
If you choose the
SPORT programs, validate "
".
To choose the
HEALTH programs, press the " " key and validate "
Scroll through the programs by pressing the " " key.
The screen first displays the 1
lower pictogram while displaying the corresponding program number at the top.
st
To go back, press the " " key.
You have now chosen the muscle zone(s) to be stimulated, and the program.
STEP 4: CHOOSE THE "wARM-UP PHASE" AND ALT SIM OPTION
(Only for programs
to
).
The screen proposes a warming-up phase before starting the active phase of the program.
The "
" WARM-UP PHASE pictogram blinks in the top right corner.
To select it, press "
", otherwise press the " " key, and validate "
Then the "
" pictogram blinks.
To select "
", press the " " key, to select "SIM", press the " " key, then validate "
If you have selected the warm-up phase, "
" is displayed when starting the program, as the warm-up phase is only in the
simultaneous mode.
The screen is displayed :
- the battery level,
- phase duration (countdown in minutes),
- timer pictogram,
- the "
" or "
" option and warm-up phase if you have selected them.
The pictogram for the program chosen is lit, the muscle zone(s) chosen blink alternately.
STEP 5: LAUNCHING THE START - ADjUSTING INTENSITY
Then, press the " " buttons of the intensity keys matching the wires connected to your electrodes to start the program.
If the battery is low, do not start the program.
The power level(s) are displayed at the bottom of the screen. The intensities vary during the session according to the program's
content.
A long press on the " " key returns the power rapidly to 0.
STEP 6: PROGRAM PERFORMANCE
Use of the " " (Clear) key:
During the program, press the " " key during a phase to set its time to zero.
The next phase starts unless you have reached the end of the program.
In this case, this key allows returning to selecting the 1
muscle zone (as at normal end of program).
st
Disconnecting the electrodes during the program :
If an electrode is disconnected, the channel concerned is reset to
During these 30 sec, the electrode(s) can be reconnected, and power restored to the level required.
STEP 7: END OF PROGRAM - STOPPING
At the end of the session, the screen proposes to start a new session by blinking the front muscles to select the 1
Restart the starting procedure if you wish to continue on another muscle zone.
Otherwise, press the " " key to stop.
The unit switches to standby after 5 minutes idle.
Recommendations:
The pictograms for upper muscles and for lower muscles are different. Avoid selecting upper muscles and lower muscles, as the unit
would give priority to upper muscles, reducing somewhat the yield of work on lower muscles.
".
".
" (it disappears from the screen).
".
and blinks for 30 sec, before returning to a fixed
.
st
muscle zone.
13