Digital Laser Measure
Dimensions
Batteries
Battery life, approximately
– Individual measurements
– Continuous measurement
A) For measurements from the rear measuring-tool edge. The working range increases depending
on how well the laser light is reflected from the surface of the target (scattered, not reflective) and
the brighter the laser point is to the ambient light intensity (interior spaces, twilight). For distances
of less than 20 m a retro-reflective target plate should not be used, as it can lead to measurement
errors.
B) For measurements from the rear measuring-tool edge, 100 % reflectance of the target (e.g., a
white-painted wall), weak backlight and 25 °C operating temperature. Additionally, a deviation in-
fluence of ±0.05 mm/m must be taken into account.
C) At 25 °C operating temperature
The measuring tool can be clearly identified with the serial number 11 on the type plate.
Assembly
Inserting/Replacing the Batteries
Using alkali-manganese or rechargeable batteries is recommended for operation of
the measuring tool.
Less measurements are possible when using 1.2 V rechargeable batteries than with
1.5 V batteries.
To open the battery lid 9, press the latch 10 in the direction of the arrow and remove
the battery lid. Insert the batteries/rechargeable batteries. When inserting, pay atten-
tion to the correct polarity according to the representation on the inside of the battery
compartment.
If the battery symbol
first appears in the display, then at least 100 measurements
are still possible. When the battery symbol is empty, you have to replace the batter-
ies/rechargeable batteries because measurements are no longer possible.
Always replace all batteries/rechargeable batteries at the same time. Do not use dif-
ferent brands or types of batteries/rechargeable batteries together.
 Remove the batteries/rechargeable batteries from the measuring tool when
not using it for longer periods. When storing for longer periods, the batteries/re-
chargeable batteries can corrode and self-discharge.
1 609 92A 23Y | (27.6.16)
PLR 25
100 x 42 x 22 mm
2 x 1,5 V LR03 (AAA)
C)
10000
C)
2.5 h
Bosch Power Tools