Bosch WEU PLR 25 Manual Original página 29

Ocultar thumbs Ver también para WEU PLR 25:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
OBJ_BUCH-2646-002.book Page 29 Monday, June 27, 2016 12:58 PM
English | 29
– Measure the distance 10 times after another.
The deviation of the individual measurements from the mean value must not exceed
±2 mm (max.). Log the measurements, so that you can compare their accuracy at a
later point of time.
Maintenance and Service
Maintenance and Cleaning
Store and transport the measuring tool only in the supplied protective pouch.
Keep the measuring tool clean at all times.
Do not immerse the measuring tool in water or other fluids.
Wipe off debris using a moist and soft cloth. Do not use any cleaning agents or sol-
vents.
Maintain the reception lens 12 in particular, with the same care as required for eye
glasses or the lens of a camera.
In case of repairs, send in the measuring tool packed in its protective pouch 17.
After-sales Service and Application Service
Our after-sales service responds to your questions concerning maintenance and re-
pair of your product as well as spare parts. Exploded views and information on spare
parts can also be found under:
www.bosch-pt.com
Bosch's application service team will gladly answer questions concerning our prod-
ucts and their accessories.
In all correspondence and spare parts orders, please always include the 10-digit arti-
cle number given on the nameplate of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a prod-
uct in need of servicing or repair.
Tel. Service: (0344) 7360109