Optional Connection
The following connections are optional. The UPS system will function properly without these
connections.
USB and Serial Communication Connection
1
Use the included USB cable
communication port of a computer to the communication port of the UPS. Install the
PowerAlert Software appropriate for the computer's operating system. Consult the
PowerAlert manual for more information.
Dry Contact Note: Dry contact communications are simple, but some knowledge of
electronics is necessary to configure them. The DB9 port's pin assignments are shown
1c
in diagram
5. If utility power fails, the UPS sends a signal by bridging pins 8 and 5. To shut the UPS
down remotely, short pin 3 and pin 9 for at least 3.8 seconds.
EPO Port Connection
2
This optional feature is only for those applications that require connection to a facility's
Emergency Power Off (EPO) circuit. When the UPS is connected to this circuit, it enables
emergency shutdown of the UPS's inverter and inhibits transfer to internal bypass. Using
the cable provided, connect the EPO port of your UPS (see
normally closed or normally open switch according to the circuit diagram (see
Note:
1. If using a cable other than what is supplied, the cable should not exceed 350
feet or have a resistance of greater than 10 ohms.
2. If a non-latching EPO switch is used, the EPO must be held for a minimum of 1
second. This does not apply to a latching EPO switch.
CAUTION: The EPO port is not a phone line surge suppressor; do not connect a
phone line to this port.
UPS Unit State when asserting EPO with AC line present:
LEDs
Output
OFF
OFF
To restart the UPS unit after asserting EPO with AC line present:
Option 1:
1. Verify that the EPO assertion has been removed or cleared.
2. Press ON button until the unit displays "STAND BY" (approx. 1 second).
3. Press ON button and UPS output will turn back on after it completes diagnostics.
Option 2:
1. Verify that the EPO assertion has been removed or cleared.
2. Remove AC line power to the UPS unit.
3. Reapply AC line power. Now the UPS will start back up in normal operation mode.
UPS Unit State when asserting EPO without AC line power:
LEDs
Output
OFF
OFF
To restart the UPS unit after asserting EPO without AC line power:
1. Verify that the EPO assertion has been removed or cleared.
2. Reapply AC line power to the UPS unit. Now the UPS will start back up in normal
operation mode.
201102169 93-2676.indd 9
1a
and/or RS-232 DB9 serial cable
. If the UPS battery is low, the UPS sends a signal by bridging pins 1 and
Fans
Serial
SNMP
ON
ON
Fans
Serial
SNMP
OFF
OFF
OFF
1b
to connect the
2a
) to a user-supplied
2b
).
USB
LCD Screen
"Emergency
ON
ON
Stop"
USB
LCD Screen
"Emergency
OFF
Stop"
9
1a
1b
1c
2a
2b EPO Pin Assignment
3/29/2011 5:08:26 PM