Water Leakage Test - Olympus PT-EP08 Manual De Instrucciones

Ocultar thumbs Ver también para PT-EP08:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 98

Water Leakage Test

The final test after loading the camera is explained below. Always perform this test. It can be performed
easily in a water tank or a bathtub. Confirm the operation of the different buttons. The required time is
about five minutes.
• At first, immerse the Case for only three seconds and check that no water enters the Case.
• Next, immerse the Case for 30 seconds and check that no water enters the Case.
• Then, immerse the Case for 3 minutes, operate all buttons and levers, and check the following:
- check that no water drops have the entered the Case.
- check that the Case is not fogged internally.
- check that no water has entered the Case.
• If the inside of the Case becomes fogged or there are water drops in the Case, repeat the maintenance
of the O-ring and perform the water leakage test again.
EN
EN 15

Publicidad

Tabla de contenido
loading

Tabla de contenido