The last 2 digits of the 4 on the bottom line give information about the status of each
of those elements. These digits may have the value "0" or "1"; value "0" indicates that
the element in question is correctly position, and "1" indicates that it is missing or not
correctly positioned.
SEG
NOTE:
The values of the first 2 digits give additional information that may be
useful for the machine After-sales service.
To prevent accidents, do not tamper with the machine to try and make it work
without the safety elements. There are three elements that act on the safety
sensors: the cover, the juice container and the peel container. The safety sensors
must be tested regularly to ensure they operate correctly. To do this, start
the machine and while it is operating, remove one of these elements to see
whether the machine stops. Put it back in place and repeat the test with the
other elements. If during any of the tests, the machine does not stop, notify the
Technical Service.
Alarms mode: The machine has automatically stopped or does not work for some
reason. When this occurs, the display will show the origin through the following alarm
codes:
1
Voltage alarm
2
Mean current alarm
3
Tipping device lock alarm
4
IA lock alarm
0010
Juice container (correctly positioned)
Cover and peel container (not correctly positioned)
5
Current alarm (thermal)
6
Short circuit current alarm
7
Miscellaneous alarms