ROBLIN Actis Electro 5741 Instrucciones De Instalación E Utilización página 9

Ocultar thumbs Ver también para Actis Electro 5741:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
green / yellow : earth
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows.
-
The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol
-
The wire which is coloured blue must be connected to the terminal which is marked with the letter N
or coloured black.
-
The wire which is coloured brown must be connected to the terminal which is marked with the letter
L or coloured red.
ATTENTION: Do not forget to use adequate plugs to the support brackets. Enquire after the manu-
facturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a
faulty hanging due to the drilling and the setting up of plugs.
The extractor unit is fitted into the base board of the cooker hood (thickness: 12 to 22 mm). (Fig 1)
Connect the electrical plug and set the extractor tube in place.
Clip the appliance into the cutout; the 4 adjustable fastening clips are made flexible to allow quick
assembly without the need for any complicated prior dismounting. Retighten the screws if necessary.
Ducting:
The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker
hood is ducted to the outside, charcoal filters are not required.The ducting used must be 150 mm (6 INS),
rigid circular pipe and must be manufactured from fire retardant material, produced to BS.476 or DIN
4102-B1. Wherever possible use rigid circular pipe which has a smooth interior, rather than the expanding
concertina type ducting.
Maximum length of ducting run:
- 4 metres with 1 x 90° bend.
- 3 metres with 2 x 90° bends.
- 2 metres with 3 x 90° bends.
The above assumes our 150 mm (6 INS) ducting is being installed.
Please note ducting components and ducting kits are optional accessories and have to be ordered,
they are not automatically supplied with the chimney hood.
•RECYCLING
The air is recirculated into the kitchen through the opening located on the upper side of the cabinet
or of the hood (Fig. 2).
Install the charcoal filters inside the canopy (Fig 3).
4
OPERATION
A - EXTRACTION OR RECYCLING :Your cooker hood is supplied in the extraction mode. To use the cooker
hood in the recycling mode re-programme the hood as follows:
blue : neutral
brown : live
or coloured green or green and yellow.
GB
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Actis electro 7741

Tabla de contenido