SeCTION 2
2.0
Description
These instructions provide installation, operation, service and parts information for the PCC-10 Plasma Coolant
Circulator. This unit recirculates coolant to cool electric arc cutting and welding equipment.
2.1
Specifications
Dimensions: 35.69" high (906 mm) x 21.75" wide (552 mm) x 25.00 deep (635 mm)
Weight: 215 lb. dry (97.5kg)/ 249 lb. wet (133kg)
Pump Type:
Positive displacement, rotary vane type with adjustable by-pass valve (200 psi/13.8 bars max.), CW rotation
as viewed from nameplate.
radiator Type: Copper tubing, aluminum finned air-to-water type with galvanized steel frame.
AC Input Voltages
AC Input Amperage
Pump Capacity
Cooling Capacity @ 2gpm
at 45° f (7° C) temperature difference between high coolant temperature and ambient air temperature.
Max. Delivery Pressure
reservoir Capacity
50hz, 1 Phase Input Power
200/230/400/460/575V., +/- 10%
9/8/5/4/3 Amperes
1.95 gpm at 100 psi
(7.4 l/min at 6.9 bars)
23,100 BTU/hr. (6800 watts)
160 psig (11 bars)
4 gallons (15.2 liters)
17
DeSCrIPTION
60hz, 1 Phase Input Power
2.33 gpm at 100 psi
(8.8 l/min at 6.9 bars)
27,720 BTU/hr. (8120 watts)